عرض بسيط للتسجيلة

المؤلفZhang, Haijun
المؤلفWang, Xiangfei
المؤلفDeng, Wei
المؤلفWang, Shenguo
المؤلفGe, Junbo
المؤلفToft, Egon
تاريخ الإتاحة2016-10-12T11:22:14Z
تاريخ النشر2016-09
اسم المنشورMedicine
المعرّفhttp://dx.doi.org/10.1097/MD.0000000000004820
الاقتباسZhang, Haijun; Wang, Xiangfei; Deng, Wei; Wang, Shenguo; Ge, Junbo; Toft, Egon "Randomized clinical trial comparing abluminal biodegradable polymer sirolimus-eluting stents with durable polymer sirolimus-eluting stents: Nine months angiographic and 5-year clinical outcomes" Medicine (2016) 95:38(e4820)
الرقم المعياري الدولي للكتاب0025-7974
معرّف المصادر الموحدhttp://hdl.handle.net/10576/4879
الملخصBackground: The biodegradable polymer drug-eluting stents (DES) were developed to improve vascular healing. However, further data and longer-term follow-up are needed to confirm safety and efficacy of these stents. This randomized clinical trial aimed to compare safety and efficacy of 2 sirolimus-eluting stents (SES): Cordimax—a novel abluminal biodegradable polymer SES and Cypher Select—a durable polymer SES, at 9 months angiographic and 5-year clinical follow-up. Methods: We randomized 402 patients with coronary artery disease to percutaneous coronary intervention with Cordimax (n = 202) or Cypher select (n = 200). Angiographic follow-up was performed at 9 months after the index procedure and clinical follow-up annually up to 5 years. The primary endpoint was angiographic in-stent late luminal loss (LLL). Secondary endpoints included angiographic restenosis rate, target vessel revascularization (TVR), and major adverse cardiac events (MACEs; defined as cardiac death, myocardial infarction, or TVR) at 5-year follow-up. Results: Cordimax was noninferior to Cypher select for in-stent LLL (0.25 ± 0.47 vs 0.18 ± 0.49 mm; P = 0.587) and in-stent mean diameter stenosis (22.19 ± 12.21% vs 19.89 ± 10.79%; P = 0.064) at 9 months angiographic follow-up. The MACE rates were not different at 1 year (5.9% vs 4.0%, P = 0.376); however, MACE rates from 2 to 5 years were lower in the Cordimax group (6.8% vs 13.1%; P = 0.039). Conclusion: Abluminal biodegradable polymer SES is noninferior to durable polymer SES at 9-month angiographic and 1-year clinical follow-up. However, MACE rates from 2 to 5 years were less in the abluminal biodegradable polymer group.
راعي المشروعNational Key Technology Research and Development Program in the Twelfth Five-year Plan Period of China (No. 2014BAI11B04).
اللغةen
الناشرWolters Kluwer Health, Inc
الموضوعabluminal biodegradable polymer
late lumen loss
major adverse cardiovascular events
sirolimus-eluting stent
العنوانRandomized clinical trial comparing abluminal biodegradable polymer sirolimus-eluting stents with durable polymer sirolimus-eluting stents: Nine months angiographic and 5-year clinical outcomes
النوعArticle
رقم العدد38
رقم المجلد95
dc.accessType Open Access


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة