Show simple item record

AuthorSleiti, Ahmad K.
AuthorAl-Ammari, Wahib A.
AuthorGamil, Ahmed I.
AuthorAl-Khawaja, Mohammed
Available date2024-02-12T10:28:10Z
Publication Date2021-01-25
Publication NameASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)
Identifierhttp://dx.doi.org/10.1115/IMECE2021-66983
CitationSleiti, A. K., Al-Ammari, W. A., Gamil, A. I., & Al-Khawaja, M. (2021, November). Supercritical Carbon Dioxide Power Cycle Integrated With Solar Power Tower and Oxy-Combustor. In ASME International Mechanical Engineering Congress and Exposition (Vol. 85635, p. V08AT08A013). American Society of Mechanical Engineers.
ISBN978-079188563-5
URIhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85124495732&origin=inward
URIhttp://hdl.handle.net/10576/51782
AbstractPower cycle that integrates solar power tower (SPT) system with direct oxy-combustion (DOC) supercritical CO2 cycle is proposed and investigated. In the SPT/DOC-sCO2 cycle (Cyc 3), the SPT works as preheater for the DOC/sCO2 system. Two more basic cycles for comparison and validation purposes are investigated including stand-alone intercooled sCO2 power cycle driven by DOC system (Cyc 1) and stand-alone basic SPT system (Cyc 2). Energy, exergy, exergoeconomic, levelized cost of electricity (LCOE) and multi-objective optimization analyses are performed for each cycle over wide range of operating pressures, temperatures and direct normal irradiance. Compared to Cyc 1 and Cyc 2, Cyc 3 has higher thermal efficiency by 6% and 2%, respectively with higher exergy efficiency and is less sensitive to cycle minimum temperature. However, the LCOE of Cyc 3 is higher due to the large capital cost of its individual CSP and DOC systems. From the optimization analyses, it is found that the decision variables of the three cycles tend toward low Pmax, higher Pmin, lower Tmax, and lower Tmin. The multi-objective optimization shows that the thermal efficiency and LCOE are 41.06% at 6.35¢/kWh for Cyc 1,45.56% at 7.86¢/kWh for Cyc 2, and 46.65% at 8.05¢/kWh for Cyc 3.
SponsorThe work presented in this publication was made possible by NPRP-S grant # [11S-1231-170155] from the Qatar National Research Fund (a member of Qatar Foundation).
Languageen
SubjectDirect oxy-fuel
Levelized cost of electricity
Multiobjective optimization
Solar power tower
Supercritical CO power cycle 2
Thermoeconomic analysis
TitleSupercritical Carbon Dioxide Power Cycle Integrated with Solar Power Tower and Oxy-Combustor
TypeConference Paper
Volume Number8A-2021


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record