Show simple item record

AuthorY. Elsayed, Mohamed
AuthorM. Sherif, Sherif
AuthorS. Aljaber, Amina
AuthorA. Swillam, Mohamed
Available date2024-03-25T06:42:38Z
Publication Date2020
Publication NameSensors (Switzerland)
ResourceScopus
ISSN14248220
URIhttp://dx.doi.org/10.3390/s20174955
URIhttp://hdl.handle.net/10576/53401
AbstractWaveguides with sub-100 nm thickness offer a promising platform for sensors. We designed and analyzed multimode interference (MMI) devices using these ultrathin platforms for use as biosensors. To verify our design methodology, we compared the measured and simulated spectra of fabricated 220-nm-thick MMI devices. Designs of the MMI biosensors based on the sub-100 nm platforms have been optimized using finite difference time domain simulations. At a length of 4 mm, the 50-nm-thick MMI sensor provides a sensitivity of roughly 420 nm/RIU and with a figure of merit (FOM) definition of sensitivity/full-width-at-half-maximum, the FOM is 133. On the other hand, using a thickness of 70 nm results in a more compact design—only 2.4 mm length was required to achieve a similar FOM, 134, with a sensitivity of 330 nm/RIU. The limits of detection (LOD) were calculated to be 7.1 × 10−6 RIU and 8.6 × 10−6 RIU for the 50 nm and the 70-nm-thick sensor, respectively. The LOD for glucose sensing was calculated to be less than 10 mg dL−1 making it useful for detecting glucose in the diabetic range. The biosensor is also predicted to be able to detect layers of protein, such as biotin-streptavidin as thin as 1 nm. The ultrathin SOI waveguide platform is promising in biosensing applications using this simple MMI structure.
SponsorThis work was supported by the American University in Cairo internal fund, and also partially supported by Qatar National Research Fund (a member of Qatar Foundation) [grant number NPRP 8-1912-1-354]. The statements made herein are solely the responsibility of the authors. Acknowledgments: The authors would like to thank Aya Zaki for helpful discussions. Fabrication and testing were made possible by the openEBL program led by Lukas Chrostowski at the University of British Columbia.
Languageen
PublisherMDPI AG
SubjectMultimode interference
Optical biosensors
Ultrathin silicon waveguides
TitleIntegrated lab-on-a-chip optical biosensor using ultrathin silicon waveguide soi mmi device
TypeArticle
Pagination12-Jan
Issue Number17
Volume Number20
dc.accessType Open Access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record