عرض بسيط للتسجيلة

المؤلفAl-Khawaja, Mohammed J.
تاريخ الإتاحة2024-04-24T11:35:19Z
تاريخ النشر2008
اسم المنشورInternational Journal of Heat and Technology
الاقتباسAL-KHAWAJA, M. J. (2008). ECONOMICAL STUDY BY DETERMINING THE OPTIMUM THICKNESS OF INSULATION OF SOME HEATERS UTILIZED IN QATAR REFINERY. INTERNATIONAL JOURNAL, 26(2), 111-114.
الرقم المعياري الدولي للكتاب0392-8764
معرّف المصادر الموحدhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=56549085714&origin=inward
معرّف المصادر الموحدhttp://hdl.handle.net/10576/54224
الملخصSome furnaces and heaters utilized in the industry in Qatar (such as Qatar Refinery) are analyzed economically by the determination of the optimum thickness of insulation for each of these equipments. Different common commercial insulations (fiber ceramics, V-19 block, and firebrick) were analyzed and compared with and without interest and escalation rates. The ceramic fiber blanket (1600 grade) was found to have the best economical performance among the three insulations analyzed for those applications. The savings would be feasible if the calculations were performed for the lifetime of the insulation.
اللغةen
الناشرInternational Information and Engineering Technology Association
الموضوعQatar
Optimum thickness
العنوانEconomical study by determining the optimum thickness of insulation of some heaters utilized in Qatar refinery
النوعArticle
الصفحات111-114
رقم العدد2
رقم المجلد26


الملفات في هذه التسجيلة

الملفاتالحجمالصيغةالعرض

لا توجد ملفات لها صلة بهذه التسجيلة.

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة