    Preventive and corrective open access system dispatch based on the voltage stability security assessment and diagnosis

    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    1-s2.0-S0378779601001602-main.pdf (210.9Kb)
    Date
    2001
    Author
    Schlueter, R.A.
    Liu, S.
    Alemadi, N.
    Metadata
    Show full item record
    Abstract
    The capabilities of the voltage stability security assessment (VSSAD) to assess proximity to and ranking voltage instability by (a) performing a contingency selection of each model determined subsystem and (b) diagnosing where, why, when and what can be done to cure voltage instability for each equipment outage and transaction combination is thoroughly documented in IEEE Trans. Power Syst. 13 (1998) 1423; Division of Engineering Research Technical Report December 1998, Santorini, Greece. This paper reviews these capabilities and how they can be used to implement a contingency selection module and security constrained optimization module for the open access system dispatch (OASYDIS) being proposed as part of the proposed transmission dispatch and congestion management (IEEE Trans. Power Syst. 13 (1998) 1466) in an ISO. The open access system dispatch can be implemented as either a preventive control as given in IEEE Trans. Power Syst. 13 (1998) 1466 or as a corrective control as proposed in this paper. The VSSAD based contingency selection can provide the security constraints for either a preventive or corrective control implementation of OASYDIS. The advantages of corrective control are discussed and the changes in the proposed open access system dispatch (IEEE Trans. Power Syst. 13 (1998) 1466) required to implement a corrective control are discussed.
    DOI/handle
    http://dx.doi.org/10.1016/S0378-7796(01)00160-2
    http://hdl.handle.net/10576/57616
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video