عرض بسيط للتسجيلة

المؤلفK Nasrallah, Gheyath
المؤلفYounes, Nadin
المؤلفKhalid, Hadiya M
المؤلفAl-Emadi, Jawaher A
المؤلفYounes, Salma
المؤلفAbouassali, Mazen Najib
المؤلفElshaikh, Manal Abdelmutaal
المؤلفKarime, Ibrahim Wisam
المؤلفIbrahim, Mohammed Abdelfatah
المؤلفAli, Mutaz Mohamed
المؤلفShaar, Ibrahim Al
المؤلفLiu, Na
المؤلفAyoub, Houssein
المؤلفYassine, Hadi M
المؤلفAbu-Raddad, Laith J
المؤلفIsmail, Ahmed
تاريخ الإتاحة2024-11-20T10:03:46Z
تاريخ النشر2024-11-15
اسم المنشورscientific reports
المعرّفhttp://dx.doi.org/10.1038/s41598-024-78271-z
الاقتباسK. Nasrallah, G., Younes, N., Khalid, H.M. et al. Evaluation of the mindray CL900i CLIA HIV Ag/Ab combo assay for sensitive and specific HIV screening compared to established methods. Sci Rep 14, 28177 (2024). https://doi.org/10.1038/s41598-024-78271-z
معرّف المصادر الموحدhttp://hdl.handle.net/10576/61416
الملخصArchitect-HIV Ag/Ab combo chemiluminescence assay is globally recognized for its sensitivity but has a notable false-positive rate. In this study, we aim to evaluate the performance of a new cost-effective screening alternative, the chemiluminescence Ag/Ab combo assay (CL-900i-HIV) from Mindray, China. We selected 195 archived samples categorized according to the INNO-LIA™ HIV I/II, the gold standard confirmatory assay. These samples included true positive (n = 38; positive by Architect-HIV & INNO-LIA-HIV), true negative (n = 101; negative by Architect-HIV & INNO-LIA-HIV), false positive (n = 20; positive by Architect-HIV & negative by INNO-LIA-HIV), and indeterminate results (n = 26). We tested all samples using the Mindray CL-900i-HIV and all positive Architect-HIV samples (n = 80) were confirmed by PCR. Compared to INNO-LIA™ HIVI/II line immunoassay confirmatory assay, Mindray CL-900i-HIV demonstrated a sensitivity of 100% (95% CI 90.7-100), specificity of 100% (95% CI 97.0-100), overall percent agreement (OPA) of 100% (95% CI 97.7-100.0), and perfect agreement with the INNO-LIA confirmatory assay (κ = 1.00). Additionally, Mindray's CL-900i-HIV exhibited a significantly lower false-positive rate (8.75%) compared to Architect-HIV's (55%). Mindray CL900i demonstrated high sensitivity and very low false-positive rate, thus, has the potential to serve as an excellent, cost-effective surrogate for HIV screening, overcoming the limitations of existing automated assays.
راعي المشروعGheyath Nasrallah would like to acknowledge receiving funds from NPRP13S-0128-200185 and UREP30-041-3-014 grants from Qatar National Research Fund (QNRF), a member of Qatar Foundation, as well as QUCG-CHS-23/24–170 from Qatar University. Houssein Ayoub, Laith Abu-Raddad and Gheyath Nasrallah would like to acknowledge receiving funds from Qatar University under grant QUCG-CAS-23/24–114. Nadin Younes would like to acknowledge receiving funds from GSRA8-L-1-0501-21022 from QNRF. It is important to note that the funders played no role in the study design, data collection, analysis, decision to publish, or preparation of the manuscript. All statements made in this report are solely the responsibility of the authors.
اللغةen
الناشرSpringer Nature
الموضوعAIDS
CLIA
Diagnosis
HIV
Infectious disease
العنوانEvaluation of the mindray CL900i CLIA HIV Ag/Ab combo assay for sensitive and specific HIV screening compared to established methods.
النوعArticle
رقم العدد1
رقم المجلد14
ESSN2045-2322
dc.accessType Open Access


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة