عرض بسيط للتسجيلة

المؤلفAmanda G., Blouin
المؤلفNelson, Wyatt
المؤلفGeraghty, Daniel
المؤلفAskar, Medhat
المؤلفYe, Fei
تاريخ الإتاحة2024-11-27T06:47:04Z
تاريخ النشر2024-11-30
اسم المنشورThe Journal of Molecular Diagnostics
المعرّفhttp://dx.doi.org/10.1016/j.jmoldx.2024.07.003
الاقتباسBlouin, A. G., Nelson, W., Geraghty, D., Askar, M., & Ye, F. (2024). Performance Characteristics of Next-Generation Sequencing–Based Engraftment Monitoring and Microchimerism Detection in Allogeneic Hematopoietic Cell Transplantation: A Practical Approach for Clinical Assay Validation. The Journal of Molecular Diagnostics, 26(11), 995-1006.
الرقم المعياري الدولي للكتاب1525-1578
معرّف المصادر الموحدhttps://www.sciencedirect.com/science/article/pii/S1525157824001818
معرّف المصادر الموحدhttp://hdl.handle.net/10576/61541
الملخصChimerism analysis by next-generation sequencing (NGS) is an emerging method for engraftment monitoring after allogeneic hematopoietic cell transplantation. A high-sensitivity method is required for the detection of microchimerism (<1% chimerism), which may have clinical utility in early relapse detection, allograft monitoring in organ transplantation, and other allogeneic cellular therapies (such as microtransplantations). As more clinical laboratories adopt this method, a thorough assessment of performance is needed. This study evaluated one such NGS-based assay that uses both single-nucleotide polymorphisms and insertions/deletions as genetic markers. An assessment of accuracy, linearity, sensitivity, and reproducibility was performed. Analytical sensitivity was 0.2% donor for single donor and 0.5% donors for double donors. The assay showed a high degree of reproducibility over a full range of chimerism. Comparison to short-tandem-repeat (STR) PCR showed high concordance; yet <5% chimerism was consistently detected by NGS, but not by STR-PCR. Comparison to real-time quantitative PCR showed high concordance, but with lower correlation in the midrange (40% to 60% chimerism). Overall, the assay showed consistent performance with high sensitivity and accuracy compared with STR-PCR and real-time quantitative PCR across a full range of chimerism in the setting of single-donor and multidonor transplantations. In addition, criteria for quality metrics were established for sequencing performance and data analysis and considerations made for clinical laboratory validation of NGS-based chimerism assay and analysis software.
راعي المشروعThis research was supported by: 1. the NIH/National Cancer Institute Cancer Center Support grant P30 CA008748 (A.G.B. and F.Y.). 2. the NIH/NCI Cancer Center Support Grant P30 CA008748.
اللغةen
الناشرElsevier
الموضوعnext-generation sequencing
Cell Transplantation
العنوانPerformance Characteristics of Next-Generation Sequencing–Based Engraftment Monitoring and Microchimerism Detection in Allogeneic Hematopoietic Cell Transplantation A Practical Approach for Clinical Assay Validation
النوعArticle
رقم العدد11
رقم المجلد26
ESSN1943-7811
dc.accessType Abstract Only


الملفات في هذه التسجيلة

الملفاتالحجمالصيغةالعرض

لا توجد ملفات لها صلة بهذه التسجيلة.

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة