Evaluating chemiluminescent immunoassays for syphilis detection: A comparative analysis
المؤلف | Ahmed, Ismail |
المؤلف | Younes, Nadin |
المؤلف | Ayoub, Houssein |
المؤلف | Nasrallah, Dana F. |
المؤلف | Al-Emadi, Jawaher A. |
المؤلف | Khalid, Hadiya M. |
المؤلف | Abouassali, Mazen Najib |
المؤلف | Elshaikh, Manal |
المؤلف | Karimeh, Ibrahim Wissam |
المؤلف | Ibrahim, Mohammed Abdelfatah |
المؤلف | Ali, Mutaz Mohamed |
المؤلف | Shaar, Ibrahim Al |
المؤلف | Younes, Salma |
المؤلف | Zein, Nouran |
المؤلف | Nizamuddin, Parveen Banu |
المؤلف | Yassine, Hadi M. |
المؤلف | Abu-Raddad, Laith J. |
المؤلف | Nasrallah, Gheyath K. |
تاريخ الإتاحة | 2025-03-27T06:59:25Z |
تاريخ النشر | 2025-06-30 |
اسم المنشور | Journal of Infection and Public Health |
المعرّف | http://dx.doi.org/10.1016/j.jiph.2025.102731 |
الرقم المعياري الدولي للكتاب | 18760341 |
الملخص | BackgroundSyphilis, caused by Treponema pallidum (TP), remains a significant global public health concern, with approximately 8 million new cases annually. Diagnosing syphilis is challenging due to its often-asymptomatic nature during latent stages, necessitating a combination of diagnostic methods. This study evaluates the performance of a novel chemiluminescent immunoassay (CLIA) developed by Mindray for detecting TP antibodies, comparing it to the widely used Abbott ARCHITECT Syphilis Treponemal Test (Architect-TP), the rapid plasma regain (RPR) test, and the Fujiribio INNO-LIA® Syphilis Score line immunoassay (INNO-LIA-TP). MethodsWe selected 180 samples that exhibited agreement or discrepancies between the RPR and Architect-TP assays. The selection included 40 cases that were RPR positive and Architect-TP positive, 40 cases that were RPR positive and Architect-TP negative, and 100 cases that were negative in both RPR and Architect-TP. All samples underwent re-testing using the Mindray-TP and INNO-LIA-TP assays. ResultsMindray-TP and Architect-TP exhibited excellent sensitivity of 100 % (95 % CI: 91–100) and specificity of 100 % (95 % CI: 97.4–100), with perfect agreement (κ= 1.00) compared to INNO-LIA-TP. Notably, 40 cases (28.6 %; 40/140) demonstrated false-positive results when using the RPR test compared to INNO-LIA-TP, indicating a substantial false-positive rate for the RPR assay. ConclusionThis study highlights the high diagnostic accuracy of the Mindray-TP assay, positioning it as a reliable and efficient tool for syphilis screening in high-volume laboratories. Given its operational efficiency and strong agreement with gold-standard assays, Mindray-TP can enhance diagnostic workflows, leading to timely syphilis detection and improved patient outcomes. |
اللغة | en |
الناشر | Elsevier |
الموضوع | Treponema pallidum Syphilis Screening STD Mindray CLIA RPR |
النوع | Article |
رقم العدد | 6 |
رقم المجلد | 18 |
Open Access user License | http://creativecommons.org/licenses/by-nc-nd/4.0/ |
ESSN | 1876-035X |
تحقق من خيارات الوصول
الملفات في هذه التسجيلة
هذه التسجيلة تظهر في المجموعات التالية
-
أبحاث مركز البحوث الحيوية الطبية [764 items ]
-
العلوم الحيوية الطبية [763 items ]
-
الرياضيات والإحصاء والفيزياء [781 items ]