    Simulation of thermal comfort and energy demand in buildings of sub-Himalayan eastern India - Impact of climate change at mid (2050) and distant (2080) future

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    1-s2.0-S2352710223002474-main.pdf (10.21Mb)
    Date
    2023-02-11
    Author
    Thapa, Samar
    Rijal, Hom Bahadur
    Pasut, Wilmer
    Singh, Ramkishore
    Indraganti, Madhavi
    Bansal, Ajay Kumar
    Panda, Goutam Kumar
    ...show more authors ...show less authors
    Metadata
    Show full item record
    Abstract
    The global warming associated with climate change predicted by the Intergovernmental Panel on Climate Change (IPCC) is expected to deteriorate the indoor climate of free-running buildings. Features like proper orientation and wall thickness are important for the design of a building that is resilient to the impact of climate change. However, the implementation of these features is sometimes difficult, especially in a rugged hilly location. A whole building simulation was performed using DesignBuilder for an existing 3-storey free running multi-family concrete building located in the sub-Himalayan region of eastern India, for thermal comfort and energy demand during the present and the climate change scenarios of 2050 and 2080. The results show an increasing trend in the indoor operative temperature during the future climatic scenario, with the condition inside the top roof-exposed floor deteriorating the most. A decrease of 59.8% and 81.2% in the annual heating energy and an increase of 221.9% and 467.0% in the annual cooling energy were predicted for the future climate of 2050 and 2080 compared to the present. Parametric analysis performed considering orientation, wall U-value, infiltration rate and window-towall ratios revealed that the east/south-east facing orientation would perform the best with regard to overheating due to climate change. Further, the use of autoclaved aerated concrete (AAC) brick is recommended along with the decrease in air infiltration rate and window-to-wall ratio to improve the thermal performance of the indoor environment. In addition, we have also proposed a method to assess the under-cooling of an indoor environment.
    DOI/handle
    http://dx.doi.org/10.1016/j.jobe.2023.106068
    http://hdl.handle.net/10576/58881
    Collections
    • Architecture & Urban Planning [‎308‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video