    Design and development of novel computer vision-based automatic calibration system for analog dial pressure gauge

    Thumbnail
    Date
    2022-07-19
    Author
    Prasad, S. J.Suji
    Indra, J.
    Thangatamilan, M.
    Meena, Radhey Shyam
    Muthusamy, Suresh
    Panchal, Hitesh
    Krishnamoorthy, Mahendran
    Sadasivuni, Kishor Kumar
    Doshi, Manish
    ...show more authors ...show less authors
    Metadata
    Show full item record
    Abstract
    Pressure gauge calibration refers to comparing the standard and test gauge to determine the error percentage. The reading accuracy of the analog dial pressure gauge is found in the conventional method through manual calculations and then tabulating the values in the calibration certificate. The present study is undertaken to increase the accuracy level of the analog dial pressure gauges. A new automated computer-based method is proposed to calibrate the meters more accurately than the conventional method. The indicated value of the pressure gauge is obtained through the angular position of the pointer and the error value is identified by comparing both standard and test gauge values. In this work, Red, Green, Blue (RGB) images of standard and test pressure gauges are acquired through a high-definition camera. After the image processing operations, the pointer orientation of the indicatoris identified, and the indicated values are calculated. The computer-vision-based automatic calibration system is applied in a 0–100-psi (0–689.476 kPa) analog dial pressure gauge, and three trials were performed to determine the accuracy. The computer vision technique improved accuracy, varying from 97 % to 98 % compared with the conventional manual observation method. The observed results have improved repeatability and accuracy with the proposed computer-vision-based system.
    URI
    https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85137149840&origin=inward
    DOI/handle
    http://dx.doi.org/10.1520/SSMS20210019
    http://hdl.handle.net/10576/42848
    Collections
    • Center for Advanced Materials Research [‎1485‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video