• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Mechanical & Industrial Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Mechanical & Industrial Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Passive pre-cooling potential for reducing building air-conditioning loads in hot climates

    Thumbnail
    Date
    2014
    Author
    Chaudhry, H.N.
    Hughes, B.R.
    Ghani, S.A.
    Metadata
    Show full item record
    Abstract
    A major source of energy consumption in the building sector is the extensive use of Heating, Ventilation and Air-Conditioning (HVAC) systems to meet the rising demands for indoor comfort. Advancements in reducing cooling loads will have a direct impact on energy consumption in the built environment. The present study investigated the thermal performance of a heat pipe heat exchanger in transferring sensible heat from high-temperature natural air streams. In order to ensure the system's sustainable operation, water was used as the working fluid and heat is transferred using its indirect evaporation phenomenon. The physical domain comprised of 19 cylindrical copper heat pipes measuring 800mm in length and 15.9mm in internal diameter, assembled in a systematic arrangement at an angle of 90° with respect to ground. The heat pipes were divided by a separator plate to segregate the evaporator and condenser ends from each other. Hot air at 41°C was delivered to the evaporator end while a temperature of 15°C was maintained in control volume at the condenser end. Computational Fluid Dynamics (CFD) was used in order to analyze the heat pipe model at fixed inlet velocities of 1m/s and 2.3m/s. The results showed a maximum temperature reduction of 3.8°C at an external air velocity of 1m/s, delivering an internal air temperature of 37.2°C. A cooling load of 976W was achieved indicating a heat pipe effectiveness of 6.4% when the velocity was increased to 2.3m/s. The numerical values predicted at the measurement locations were compared against experimental results for the purpose of validation. Good correlation was observed between the two techniques with error variations of 10% for air velocity and 28% for air temperature. The present study identified the potential of sustainable pre-cooling using a heat pipe heat exchanger in natural ventilation air streams for regions incorporating hot and dry climatic conditions.
    DOI/handle
    http://hdl.handle.net/10576/4454
    Collections
    • Mechanical & Industrial Engineering [‎1461‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video