    Proposing a Nondestructive and Intelligent System for Simultaneous Determining Flow Regime and Void Fraction Percentage of Gas-Liquid Two Phase Flows Using Polychromatic X-Ray Transmission Spectra

    Thumbnail
    Date
    2021
    Author
    Amiri, Saba
    Ali, Peshawa Jammal Muhammad
    Mohammed, Shivan
    Hanus, Robert
    Abdulkareem, Lokman
    Alanezi, Adnan Alhathal
    Eftekhari-Zadeh, Ehsan
    Roshani, Gholam Hossein
    Nazemi, Ehsan
    Kalmoun, El Mostafa
    ...show more authors ...show less authors
    Metadata
    Show full item record
    Abstract
    Two phase flows are of particular importance in various research fields. In the current article, a novel system consists of an X-ray tube and one sodium iodide crystal detector with ability of determining type of flow regime as well as void fraction percentage of a two phase flow, is proposed. MCNP-X code was used for physical modelling of the proposed system and its performance. Radial basis function (RBF) was also implemented for analyzing and classifying the obtained data from the proposed system. Counts in each 1 keV energy bin of photon energy spectra in the detector were inserted in RBF as inputs data set and flow regime and void fraction percentage were obtained as the two outputs. After training the RBF network, the system could simultaneously recognize all the flow regimes and predict the void fraction percentage of a modelled liquid-gas two-phase flow with an acceptable error. The proposed methodology in the present paper has three main novelties and advantages over former studies. Firstly, in this system an X-ray tube is used compared to previous studies where one or more radioisotope sources served as radiation source in a radiation based multi-phase flow meter. Secondly, in former works at least two detectors were used to recognize type of flow pattern and meter volume fractions simultaneously, while in this study only one detector is utilized. Thirdly, in this study just one neural network is used, while in other studies more than one network was used.
    DOI/handle
    http://dx.doi.org/10.1007/s10921-021-00782-w
    http://hdl.handle.net/10576/54562
    Collections
    • Mathematics, Statistics & Physics [‎805‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video