Show simple item record

AuthorHassab, M.A.
AuthorTag, I.A.
Available date2009-11-25T13:06:31Z
Publication Date1990
Publication NameEngineering Journal of Qatar University
CitationEngineering Journal of Qatar University, 1990, Vol. 3, Pages 111-133.
URIhttp://hdl.handle.net/10576/7985
AbstractThis work is devoted to the gaining of insight into the operation of environmentally controlled greenhouse in hot and humid climates. Field data inside and outside the greenhouse, namely: solar radiation, dry and wet bulb ambient temperature, relative mumidity, wind speeds, rainful and the three-dimensional greenhouse temperature disrtribution are presented over a two-year period the life project. Based on the local climatological conditions, the operational schedule of greenhouse equipment for; evaporative coolers, mechanical coolers, ventilators, gas heaters and shading is identified. In this locality, evaporative coolers adequately control the daytime greenhouse environment except for several hot and humid summer weeks. Mechanical coolers are required for summer nights. Gas heaters are only employed for cold winter nights. For this particular type of greenhouse where the pads are placed opposite to the fans, two temperature zones are identified. The lower zone, characterized by the height of the plant - which is less than pad height - maitains a temperature much lower than that of the upper one.
Languageen
PublisherQatar University
SubjectEnergy
TitlePerformance of Greenhouses in The Arabian Gulf
TypeArticle
Pagination111-133
Volume Number3


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record