Search
Now showing items 1391-1400 of 3867
Investigation of inter-line dynamic voltage restorer with virtual impedance injection
(
IEEE
, 2010 , Conference Paper)
The Inter-Line Dynamic Voltage Restorer (IDVR) consists of several voltage source inverters connected to different independent distribution feeders with common dc bus. When one of the inverters compensates for voltage sag ...
Comparative evaluation of four quasi-square wave fed multiphase induction machines
(
IEEE
, 2011 , Conference Paper)
Multiphase winding structures provide induction machines with favorable fault tolerant characteristics. Medium voltage drives have also benefited from the favorable application characteristics of multiphase machines, as ...
Assessment of fault-ride through capability of grid-connected brushless DFIG wind turbines
(
Institution of Engineering and Technology
, 2011 , Conference Paper)
DFIGs are reported to suffer serious reliability problems due to the presence of slip-rings, brushes and gearbox. These disadvantages encouraged several research groups to investigate the viability of employing single-frame ...
An active damping technique for a current source inverter employing a virtual negative inductance
(2010 , Conference Paper)
A grid connected CSI requires a CL filter stage. In this work, the isolation transformer leakage inductance constitutes this filter inductance. This CL filter is lightly damped for efficiency constraints. Hence, it is ...
Inverter-based versus synchronous-based distributed generation; Fault current limitation and protection issues
(
IEEE
, 2010 , Conference Paper)
The contribution of distributed generation (DG) to network fault levels depends heavily on the technology employed. In the case of directly connected rotating machines the fault behavior is well established; with synchronous ...
New voltage regulation techniques for low voltage radial feed PWM inverter based distributed networks
(2010 , Conference Paper)
Grid voltage rise problems occur, especially at light loads, due to the proliferation of distributed generation. Two techniques are proposed for regulating the voltage in low voltage radial networks when inverter based ...
Fault ride-through capability enhancement based on flywheel energy storage system for wind farms connected via VSC high voltage DC transmission
(
Institution of Engineering and Technology
, 2012 , Conference Paper)
This paper proposes a recovery strategy for wind energy-fed voltage source converter high voltage DC transmission systems, capable of maintaining power balance between the AC and DC sides during different AC faults. This ...
Single phase grid connected current source inverter: Mitigation of oscillating power effect on the grid current
(
Institution of Engineering and Technology
, 2011 , Conference Paper)
Although voltage source inverters (VSIs) are the most common DC-AC grid-tied converters, current source inverters (CSIs) are considered to be promising candidate, thanks to their low THD voltages/currents and inherent ...
Static synchronous series compensator for low voltage ride through capability of wind energy systems
(
IET
, 2011 , Conference Paper)
Due to the large increase in number of installed high power renewable energy generating systems such as wind energy power plants, one of the important evolving requirement is riding through the fault at low or zero voltage. ...
Unified power flow controller for low voltage ride through capability of wind-based renewable energy grid-connected systems
(
IEEE
, 2011 , Conference Paper)
Due to the large increase in number of installed high power renewable energy generating systems such as wind energy power plants, one of the important evolving requirement is riding through the fault at low or zero voltage. ...