• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Performance assessment of single and dual loops discrete PR controllers with LCL filter for inverter-based distributed generation

    Thumbnail
    Date
    2014
    Author
    El-Deeb, H. M.
    Elserougi, A.
    Abdel-Khalik, A.S.
    Ahmed, S.
    Massoud, Ahmed
    Metadata
    Show full item record
    Abstract
    Due to the rapid growth of the electric energy demands, the necessity of involvement of distributed generation (DG) to overcome this demand became a must. When distributed generation renewable energy sources are coupled to the grid through a DC-AC inverter, the injected currents to the grid should be characterized by high quality and low distortion. Many factors play an important role to produce high quality output beginning with the order of the passive filter used, type of controller used and last but not least the presence of distortions in the grid. This paper demonstrates the evaluation of performance, in normal and abnormal grid conditions, between single and dual loop control for the three phase inverter tied to the grid through a LCL passive filter and controlled with discrete proportional resonant (PR) controller, taking into account how filter parameters, control gains and sampling frequency would affect the dynamics of the system as well as its stability in order to perform adequate tuning. The concluded assumptions were simulated & verified through Matlab/Simulink.
    DOI/handle
    http://dx.doi.org/10.1109/SPEEDAM.2014.6872120
    http://hdl.handle.net/10576/28812
    Collections
    • Electrical Engineering [‎2822‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video