• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A wireless oxygen saturation and heart rate monitoring and alarming system based on the Qatar Early Warning Scoring system

    Thumbnail
    View/Open
    jemtac.2016.icepq.155.pdf (207.0Kb)
    Date
    2016
    Author
    Alshorman, Sami Saleh
    Bensaali, Faycal
    Jaber, Fadi
    Metadata
    Show full item record
    Abstract
    Background: Peripheral oxygen saturation (SpO2) and heart rate (HR) are important indicators for various medical conditions such as cardiopulmonary disorders and respiratory diseases. The main objectives of this study is to design and implement a portable embedded medical system. This system wirelessly obtains SpO2 and HR data from a patient as well as his/her coordination, and sends a short messaging service (SMS) alarm to the emergency control room to contact the patient and confirm his/her health status or dispatch an ambulance in case of his/her measurements are outside the normal range based on the Qatar Early Warning Scoring (QEWS) system. Methods: The system mainly consists of a Bluetooth finger pulse oximeter, a Bluetooth-enabled microcontroller, a global positioning system (GPS) and a General Packet Radio Service (GPRS) module. It is divided into three main stages. In the first stage, the readings of SpO2 and HR are obtained from the patient in real time. During the second stage, the readings obtained are sent over Bluetooth to the signal acquisition and processing unit. The received data is processed and a decision is made whether a SMS alarm should be sent or not. The final stage is concerned with sending the alarming SMS to the emergency control room over the GPRS network based on the QEWS system. Results: The system was implemented and successfully tested as a stand-alone unit by avoiding the use of a PC or a smartphone for data processing. The transmitted SMS alarm includes the SpO2 and HR readings, the QEWS score and the GPS coordinates. Conclusions: The designed system is wireless, portable, and user-friendly. This system possibly promotes quality of care for the patient living outside hospital and could improve response time from an ambulance service point of view by determining the exact location of the patient.
    URI
    https://doi.org/10.5339/jemtac.2016.icepq.155
    DOI/handle
    http://hdl.handle.net/10576/28943
    Collections
    • Electrical Engineering [‎2823‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video