Search
Now showing items 51-60 of 71
Capacitor voltage balancing using redundant states of space vector modulation for five-level diode clamped inverters
(
IEEE
, 2010 , Article)
A redundancy balancing technique for the five-level diode-clamped inverter is presented, which balances the four dc-link capacitor voltages at high modulation index and high power factor. The technique is based on dividing ...
Investigation of inter feeder power flow regulator: Load sharing mode
(2010 , Article)
The Inter feeder Power Flow Regulator (IFPFR) proposed in this paper consists of several voltage source inverters with common dc bus; each inverter is connected in series with one of different independent distribution ...
Ride-through capability of grid-connected brushless cascade DFIG wind turbines in faulty grid conditions-A comparative study
(
IEEE
, 2013 , Article)
Doubly-fed induction generator (DFIG)-based wind turbines (WTs) are reported to suffer reliability problems due to the presence of slip-rings, brushes, and the gearbox. These disadvantages encouraged several research groups ...
Optimum power transmission-based droop control design for multi-terminal HVDC of offshore wind farms
(
IEEE
, 2013 , Article)
Power generation through wind is expected to play a major role in the world's future energy portfolio. Nevertheless, wind power integration remains a challenging research area due to the special characteristics of wind ...
Effect of stator winding connection of five-phase induction machines on torque ripples under open line condition
(
Institute of Electrical and Electronics Engineers Inc.
, 2015 , Article)
One of the main challenges in designing high-power drive systems is the quality of the developed torque. High-torque-ripple magnitudes result in serious vibration and acoustic noise problems that affect the lifetime of a ...
A modified stationary reference frame-based predictive current control with zero steady-state error for LCL coupled inverter-based distributed generation systems
(
IEEE
, 2011 , Article)
This paper proposes a modified stationary reference frame-based predictive current controller with zero steady-state error for LCL coupled inverter-based distribution generation systems. Analytical expressions for the ...
An improved performance direct-drive permanent magnet wind generator using a novel single-layer winding layout
(
IEEE
, 2013 , Article)
Direct-drive permanent magnet (PM) generators have become a strong contender in medium and large rating wind energy conversion systems as they not only provide higher efficiency and annual energy production, but also reduce ...
Studying the effect of over-modulation on the output voltage of three-phase single-stage grid-connected boost inverter
(
Elsevier B.V.
, 2013 , Article)
Voltage boosting is very essential issue in renewable-energy fed applications. The classical two-stage power conversion process is typically used to interface the renewable energy sources to the grid. For better efficiency, ...
DC-link capacitor voltage balancing for a five-level diode-clamped active power filter using redundant vectors
(2013 , Article)
This paper investigates the compensation and modulation processes of the five- level diode-clamped active power filter, compensating a three-phase rectified resistor-inductor load with redundant vectors. From the analysis, ...
Switched mode power supplies for charge-up, discharge and balancing dc-link capacitors of diode-clamped five-level inverter
(
IET
, 2010 , Article)
Inductor switch mode power supplies (SMPS) operated in a discontinuous inductor current mode are used to balance the dc-link capacitor voltages of a diode-clamped five-level inverter. The SMPS concept is extended to charge ...