Search
Now showing items 1-2 of 2
Operation of three-phase modular multilevel converter (MMC) with reduced number of arms
(
Institute of Electrical and Electronics Engineers Inc.
, 2016 , Conference Paper)
Conventional three-phase MMC consists of six-arms, each arm is controlled to generate unipolar voltage ranging from zero to Vdc where Vdc is the input DC voltage. Each arm voltage has two components (DC and AC components). ...
A new three-level switched-capacitor submodule for modular multilevel converters
(
Institute of Electrical and Electronics Engineers Inc.
, 2016 , Conference Paper)
Conventionally, only one out of the two capacitors in a three-level submodule is involved in the arm current path to generate the first non-zero voltage level (E) in modular multilevel converters (MMCs). While two capacitors ...