• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    An Accurate Non-Pilot Scheme for Accelerated Trip of Distance Relay Zone-2 Faults

    Thumbnail
    Date
    2021
    Author
    Ghorbani, Amir
    Mehrjerdi, Hasan
    Sanaye-Pasand, Majid
    Metadata
    Show full item record
    Abstract
    The delayed operation of distance relays zone-2 element for the faults at the end of the line is excessive. It reduces the fault clearing speed and therefore, is one of the main factors that can endanger power system stability. This paper proposes an impedance-based scheme for discrimination between the last 20% of the line length faults and the adjacent line faults, which are covered by the relay zone-2. The suggested non-pilot scheme uses a modified fault location formula for the accelerated zone-2 operation of distance relays. The negative- and zero-sequence components of local signals are utilized to calculate the accurate fault location after the remote circuit breaker (CB) operation. The proposed algorithm is independent of fault resistance, power flow direction, pre-fault condition, and it can clearly distinguish internal faults from the adjacent line faults. Simulation results show that the proposed method can identify the remote CB operation and thus can accelerate the tripping of zone-2 within a very short time for different fault locations, fault types, fault resistances, and load angles. Also, accurate fault location has been achieved under all simulation conditions. 1986-2012 IEEE.
    DOI/handle
    http://dx.doi.org/10.1109/TPWRD.2020.3007559
    http://hdl.handle.net/10576/36313
    Collections
    • Electrical Engineering [‎2823‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video