عرض بسيط للتسجيلة

المؤلفChowdhury, Moajjem H.
المؤلفShuzan, Md N.
المؤلفChowdhury, Muhammad E.H.
المؤلفMahbub, Zaid B.
المؤلفUddin, M. M.
المؤلفKhandakar, Amith
المؤلفReaz, Mamun B.
تاريخ الإتاحة2023-04-17T06:57:47Z
تاريخ النشر2020
اسم المنشورSensors (Switzerland)
المصدرScopus
معرّف المصادر الموحدhttp://dx.doi.org/10.3390/s20113127
معرّف المصادر الموحدhttp://hdl.handle.net/10576/42000
الملخصHypertension is a potentially unsafe health ailment, which can be indicated directly from the blood pressure (BP). Hypertension always leads to other health complications. Continuous monitoring of BP is very important; however, cuff-based BP measurements are discrete and uncomfortable to the user. To address this need, a cuff-less, continuous, and noninvasive BP measurement system is proposed using the photoplethysmograph (PPG) signal and demographic features using machine learning (ML) algorithms. PPG signals were acquired from 219 subjects, which undergo preprocessing and feature extraction steps. Time, frequency, and time-frequency domain features were extracted from the PPG and their derivative signals. Feature selection techniques were used to reduce the computational complexity and to decrease the chance of over-fitting the ML algorithms. The features were then used to train and evaluate ML algorithms. The best regression models were selected for systolic BP (SBP) and diastolic BP (DBP) estimation individually. Gaussian process regression (GPR) along with the ReliefF feature selection algorithm outperforms other algorithms in estimating SBP and DBP with a root mean square error (RMSE) of 6.74 and 3.59, respectively. This ML model can be implemented in hardware systems to continuously monitor BP and avoid any critical health conditions due to sudden changes. 2020 by the authors. Licensee MDPI, Basel, Switzerland.
راعي المشروعFunding: This work was made possible by NPRP12S-0227-190164 from the Qatar National Research Fund, a member of Qatar Foundation, Doha, Qatar. The statements made herein are solely the responsibility of the authors.
اللغةen
الناشرMDPI AG
الموضوعBlood pressure
Feature selection algorithm
Machine learning
Photoplethysmograph
العنوانEstimating blood pressure from the photoplethysmogram signal and demographic features using machine learning techniques
النوعArticle
رقم العدد11
رقم المجلد20
dc.accessType Abstract Only


الملفات في هذه التسجيلة

الملفاتالحجمالصيغةالعرض

لا توجد ملفات لها صلة بهذه التسجيلة.

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة