• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Automated detection of perinatal hypoxia using time-frequency-based heart rate variability features

    Thumbnail
    Date
    2014-02
    Author
    Dong, Shiying
    Boashash, Boualem
    Azemi, Ghasem
    Lingwood, Barbara E.
    Colditz, Paul B.
    Metadata
    Show full item record
    Abstract
    Perinatal hypoxia is a cause of cerebral injury in foetuses and neonates. Detection of foetal hypoxia during labour based on the pattern recognition of heart rate signals suffers from high observer variability and low specificity. We describe a new automated hypoxia detection method using time-frequency analysis of heart rate variability (HRV) signals. This approach uses features extracted from the instantaneous frequency and instantaneous amplitude of HRV signal components as well as features based on matrix decomposition of the signals' time-frequency distributions using singular value decomposition and non-negative matrix factorization. The classification between hypoxia and non-hypoxia data is performed using a support vector machine classifier. The proposed method is tested on a dataset obtained from a newborn piglet model with a controlled hypoxic insult. The chosen HRV features show strong performance compared to conventional spectral features and other existing methods of hypoxia detection with a sensitivity 93.3 %, specificity 98.3 % and accuracy 95.8 %. The high predictive value of this approach to detecting hypoxia is a substantial step towards developing a more accurate and reliable hypoxia detection method for use in human foetal monitoring.
    DOI/handle
    http://dx.doi.org/10.1007/s11517-013-1129-3
    http://hdl.handle.net/10576/4288
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video