Impact of Harmonics of Distributed Generators on the Harmonic Profiling of Distribution Networks
Abstract
Distributed generators (DGs) have emerged as a go-to solution to accommodate increasing loads, with the existing grid infrastructure. The DG-injected power can be consumed locally, thereby reducing the grid current and improving the voltage profile. The power-electronics interface-based DGs, controlled as current sources, employ a grid-side filter for injecting sinusoidal current into the grid. As the filter is designed to meet IEEE compliance for DG grid integration, the current THD is restricted to less than 5%. Although the compliance is met, these harmonics injected into the grid significantly deteriorate the harmonic profile of the entire grid. This study quantifies the impact of two types of DGs - constant power DGs (Type-1) and varying power DGs (Type-II) on the utility grid. An actual 24-hour data-based IEEE 33-bus distribution network, consisting of both linear and non-linear loads, is used to quantify the DGs' harmonic impact. Post-DGs addition, it is observed that Type-I DGs increase the voltage THD by at least 1% at the farthest nodes, although the pattern remains consistent with that of prior DG addition. However, with Type-II DGs, the profile obtained is further deteriorated and inconsistent and exhibits a strong dependence on the power generation of the DG. 2023 IEEE.
Collections
- Electrical Engineering [2649 items ]
Related items
Showing items related by title, author, creator and subject.
-
Harmonic rejection in current source inverter-based distributed generation with grid voltage distortion using multi-synchronous reference frame
Morsy, A.; Ahmed, S.; Massoud, Ahmed ( Institution of Engineering and Technology , 2014 , Article)The growing penetration of renewable energy resources and distributed generation (DG) has raised significant interest in power quality issues. Achieving low total harmonic distortion of exported current using low switching ... -
Effect of current harmonic injection on constant rotor volume multiphase induction machine stators: A comparative study
Abdel-Khalik, A. S.; Masoud, M. I.; Ahmed, S.; Massoud, Ahmed ( IEEE , 2012 , Article)Although torque enhancement in multiphase induction machines using harmonic current injection has been addressed in the literature, a detailed assessment of the effect of this enhancement on the design parameters of ... -
Selective harmonic elimination for quasi seven-level operation of cascaded-type multilevel converters with unequal DC sources
Fakhry, M.G.; Massoud, Ahmed; Ahmed, S. ( Institute of Electrical and Electronics Engineers Inc. , 2015 , Conference Paper)Generally, selective harmonic elimination (SHE) complexity for multilevel converters increases with the increase in number of levels. In this paper, an approach for multilevel converters' SHE is introduced. This approach ...