Integrated sensing technologies for detection and location of leaks in water distribution networks
المؤلف | Hawari, Alaa |
المؤلف | Khader, Mohammad |
المؤلف | Hirzallah, Walaa |
المؤلف | Zayed, Tarek |
المؤلف | Moselhi, Osama |
تاريخ الإتاحة | 2023-05-23T09:39:16Z |
تاريخ النشر | 2017 |
اسم المنشور | Water Supply |
المصدر | Scopus |
الملخص | Water distribution networks (WDNs) are infrastructure systems that have high socioeconomic values, for which efficient operation and management are required to ensure minimal amounts of waste which can be represented in the form of leaks. Leak detection is considered as one of the challenges faced by municipalities operating WDNs because it either involves shutting down the system or requires using expensive equipment and technologies. In this paper, a novel noninvasive and nondestructive methodology for detecting leaks in water pipes was tested. Ground penetrating radar was used for accurate determination of pipe location, followed by infrared (IR) thermographic imaging for determining the leak location using four different operating conditions. Results were statistically analyzed using analysis of variance and pairwise comparison methods. Several factors were found to affect the accuracy of the proposed methodology in predicting the leak location, namely, the characteristics of the studied surface (i.e. emissivity), the characteristics of the surrounding environment (i.e. ambient temperature and relative humidity), and the operating conditions of the IR camera (i.e. speed and height of the camera). The results obtained in this study have also shown that under high ambient temperatures and high relative humidity conditions, a higher speed of the IR camera would reduce the impact of noise on the collected thermal contrast and therefore, would give better leak location prediction results. The tested methodology proved the flexibility of the approach and the ability of accurately predicting the leak locations under different conditions. IWA Publishing 2017. |
راعي المشروع | This publication was made possible by NPRP grant # (NPRP-5-165-2-055) from the Qatar National Research Fund (a member of The Qatar Foundation). The statements made herein are solely the responsibility of the authors. The authors would also like to acknowledge the Qatar General Electricity and Water Corporation (KAHRAMAA) for their cooperation and help. |
اللغة | en |
الناشر | IWA Publishing |
الموضوع | ground penetrating radar non-destructive thermography water leakage water pipelines |
النوع | Article |
الصفحات | 1589-1601 |
رقم العدد | 6 |
رقم المجلد | 17 |
الملفات في هذه التسجيلة
الملفات | الحجم | الصيغة | العرض |
---|---|---|---|
لا توجد ملفات لها صلة بهذه التسجيلة. |
هذه التسجيلة تظهر في المجموعات التالية
-
الهندسة المدنية [850 items ]