• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    ANN-based system for a discrimination between unbalanced supply voltage and phase loss in induction motors

    Thumbnail
    Date
    2014
    Author
    Refaat, Shady S.
    Abu-Rub, Haitham
    Iqbal, Atif
    Metadata
    Show full item record
    Abstract
    It is documented that almost 98% of all voltage generated by electric utilities has up to 3% unbalance. Single phasing fault deserves special attention since phase loss is considered the worst case of unbalanced supply voltage. This paper focuses on unbalanced supply condition diagnosis and discrimination between an unbalance in the supply and phase loss fault. The discrimination will be based on the ratio of third harmonic to fundamental Fast Fourier Transform (FFT) magnitude components (RTHF-FFT) of the three-phase stator line currents and supply voltages under different load conditions and using artificial neural network (ANN). The proposed approach achieves high accuracy in detecting the unbalanced supply voltage condition in induction motor and identifying the level of severity of the fault. In addition, the proposed algorithm will discriminate between the effects of unbalanced supply voltage and those due to phase losses fault. The paper proposed a reliable approach for detection and diagnosis of unbalanced supply voltage condition. Possible loss of winding insulation under different percentages of unbalanced supply voltages will be predicted which could help preventing sudden failure of the motor during operation. The approach will be proved through experimental validation.
    DOI/handle
    http://dx.doi.org/10.1049/cp.2014.0325
    http://hdl.handle.net/10576/4484
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video