Show simple item record

AuthorXu, Jinlong
AuthorButler, Liam J
AuthorElshafie, Mohammed ZEB
Available date2024-08-05T07:19:20Z
Publication Date2020
Publication NameStructural Health Monitoring
ResourceScopus
ISSN14759217
URIhttp://dx.doi.org/10.1177/1475921719834506
URIhttp://hdl.handle.net/10576/57439
AbstractPrestressed concrete sleepers with built-in fibre optic-based sensing systems have recently been developed to capture performance data within railway networks and to provide critical decision-support information to route managers and operators. To better understand how self-sensing sleepers can be fully utilized within the rail network, a study of their comprehensive performance under controlled conditions must be undertaken. This article presents the results of the full-scale laboratory testing of a self-sensing sleeper supported on ballast. A primary focus of this study was to investigate whether a self-sensing sleeper could also be used to estimate rail seat load, detect cracking, and identify differential ballast settlement. The ultimate capacity and resilience of the embedded fiber Bragg grating sensing system was tested by applying load up until concrete cracking followed by several cyclic load cycles. Through inference of the load versus strain response, the ability of the self-sensing sleeper to detect damage (concrete cracking and loss of ballast support) was evaluated. The experimental results revealed the effectiveness and robustness of the embedded sensing system to continue to provide reliable dynamic strain measurements well beyond the ultimate loading capacity of the prestressed sleeper. Cracking of the top surface of the sleeper was effectively detected by the fiber Bragg grating strain sensors at the mid-span section. After cracking, subsequent load cycles were carried out. During this period, the bottom fiber Bragg grating measurements captured the effects of differential ballast settlement under the rail seats. A three-dimensional nonlinear finite element model was developed to simulate the experimental test setup and to investigate the relation between fiber Bragg grating sensor measurements and rail track response. The combined experimental and numerical results suggest that a self-sensing sleeper may be deployed on an operational railway to provide reliable and long-term measurements of rail axle load and ballast pressure.
SponsorThe authors gratefully acknowledge the invaluable use and facilitation of Heriot-Watt University testing facilities from Demetrios Kotsovos, the assistance with self-sensing sleeper fabrication of Paul Crowther and Stewart Smith of CEMEX, the on-site instrumentation assistance of Jason Shardelow and Niamh Gibbons of the University of Cambridge. Additional data related to this publication are available at the University of Cambridge data repository. This work was supported by EPSRC and Innovate UK through the Cambridge Centre for Smart Infrastructure and Construction (CSIC) Innovation and Knowledge Centre (EPSRC grant reference number EP/L010917/1).
Languageen
PublisherSAGE Publications Ltd
Subjectdamage detection
experimental testing
Fibre optic sensors
finite element analysis
prestressed concrete sleepers
railways
structural condition monitoring
TitleExperimental and numerical investigation of the performance of self-sensing concrete sleepers
TypeArticle
Pagination66-85
Issue Number1
Volume Number19
dc.accessType Abstract Only


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record