    Adaptive generalized predictive voltage control of islanded ac microgrid in presence of symmetric and asymmetric faults

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    Date
    2024-01-01
    Author
    Felegari, Bashir
    Asvadi-Kermani, Omid
    Oshnoei, Arman
    Momeni, Hamidreza
    Muyeen, S. M.
    Metadata
    Show full item record
    Abstract
    In islanded microgrids, efficiently controlling the output voltage and frequency of voltage source inverters while maintaining stability poses a significant challenge, particularly during grid fault conditions. This paper presents an online adaptive Kalman-based constrained generalized predictive voltage controller (AGPVC) that there are constraints on the inverter control signal and its changes to maintain microgrid s’ voltage and frequency are stayed within the specified limits and restore them to reference values after short circuit faults, after the system s’ dynamic changes. Notably, the proposed controller operates without requiring knowledge of the system's physical parameters, relying solely on local information to regulate the inverter output. The constrained and adaptive model estimation mechanisms increase the stability and scalability of the proposed method for implementation on the different systems. The transient and steady-steady state response of the output voltage in both normal and faulty conditions shows that for the 380 V reference maximum voltage drop during fault is 40 V less than the traditional method after the fault happens. The effectiveness of the proposed controller is verified through time-domain simulations conducted in MATLAB/Simulink.
    URI
    https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85175148332&origin=inward
    DOI/handle
    http://dx.doi.org/10.1016/j.epsr.2023.109964
    http://hdl.handle.net/10576/62211
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video