• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Dental Medicine
  • Dental Medicine Research
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Dental Medicine
  • Dental Medicine Research
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Trueness and precision of facial scan and virtual patient representation workflow

    Thumbnail
    View/Open
    Journal of Prosthodontics - 2025 - Al Hamad - Trueness and precision of facial scan and virtual patient representation.pdf (1.962Mb)
    Date
    2025-01-21
    Author
    Al Hamad, Khaled Q.
    Ayyad, Jad Q.
    Al-Rashdan, Bashar A.
    Al Quran, Firas A.
    Metadata
    Show full item record
    Abstract
    Purpose: To investigate the feasibility and accuracy (trueness and precision) of facial scanning and virtual patient representation (VPR). Materials and Methods: One participant was recruited and informed consent was obtained. VPR was performed 30 times with a custom fabricated intraoral scan body (ISB). Thirteen adhesive markers were added to the face as an extraoral scan body (ESB). Two facial scans were obtained for each VPR using an infra-red laser accessory sensor (Structure sensor; Occipital Inc) mounted on a computer tablet (iPad Pro; Apple Inc), including one with seated ISB and one without ISB. Two maxillary intraoral scans were obtained using an intraoral scanner (Omnicam; Dentsply Sirona) with and without the ISB. All files were imported to a dental software program (exocad; exocad GmbH) and VPR was obtained by aligning the facial and IOS scans using the ISB and ESB as common elements for alignment. Five fiducial face landmarks, four intraoral dental landmarks, and six perioral landmarks were selected for measurements. A total of 32 linear measurements, including 14 face-face (for facial scan accuracy) and 18 face-dental (for VPR accuracy) representing total face, lower face, and perioral regions, were performed directly using a digital caliper (FINO Digital Caliper; FINO GmbH) and virtually on the VPR. Trueness was evaluated by mean absolute difference (MAD) between the virtual and direct measurements, and the standard deviation represented Precision. Statistical analyses were performed with a statistical software package (IBM SPSS Statistics v25; IBM Corp), with α = 0.05. Data were analyzed for normality with Shapiro-Wilk test, and 1-sample t- (or Wilcoxon signed rank test), technical error of measurement (TEM), and relative error magnitude (REM). Results: The facial scan had 2.04, 1.66, 0.8 trueness, and 1.05, 0.92, 0.91 precision for total, lower face, and perioral regions. VPR had higher MAD (lower trueness) than facial scan, including 3.32, 2.40, 1.21 trueness and 2.2, 1.47, 1.2 precision for total, lower face, and perioral regions. Both TEM and REM were lowest for the perioral region and increased with increasing measurement distance. Conclusion: Error in face scanning increased with increased distance and intricate details. VPR accuracy was lower than face scan accuracy because of added errors in the alignment process. The investigated VPR workflow might be feasible for treatment planning and smile design. However, it would be unreliable for more demanding prostheses manufacturing purposes.
    URI
    https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85215594462&origin=inward
    DOI/handle
    http://dx.doi.org/10.1111/jopr.14024
    http://hdl.handle.net/10576/64018
    Collections
    • Dental Medicine Research [‎424‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video