Accre 8 emerging point of care CLIA system for vitamin B12 assessment compared with three established assays
المؤلف | Trad, Farah M. |
المؤلف | AlHamad, Tasneem |
المؤلف | Younes, Nadin |
المؤلف | Abunasser, Shaden |
المؤلف | Younes, Salma |
المؤلف | Nizamuddin, Parveen B. |
المؤلف | Chaar, Dayana El |
المؤلف | Salameh, Israa M. |
المؤلف | Al-dewik, Nader I. |
المؤلف | Laiwattanapaisal, Wanida |
المؤلف | Aungbamnet, Pattramon |
المؤلف | Loungjinda, Pollanat |
المؤلف | Ammaranond, Palanee |
المؤلف | Li, Meng |
المؤلف | Abu-Raddad, Laith J. |
المؤلف | Nasrallah, Gheyath K. |
تاريخ الإتاحة | 2025-05-27T05:41:25Z |
تاريخ النشر | 2025 |
اسم المنشور | Scientific Reports |
المصدر | Scopus |
المعرّف | http://dx.doi.org/10.1038/s41598-025-97503-4 |
الرقم المعياري الدولي للكتاب | 20452322 |
الملخص | Accurate Vitamin B12 (Vit B12) quantification is essential for diagnosing deficiencies linked to neurological and hematological disorders. The Accre 8 Point-of-Care (POC) Chemiluminescent Immunoassay (CLIA) system offers a compact design, rapid single-step operation, and minimal calibration requirements. This study evaluates Accre 8's performance against established CLIA immunoassays (Abbott and Roche) and LC-MS/MS, the gold standard for Vit B12 quantification. A total of 297 serum samples, spanning deficient to sufficient Vit B12 levels, were analyzed. Accre 8 demonstrated a strong correlation with LC-MS/MS (r = 0.94, p < 0.001), with median Vit B12 levels closely aligning with LC-MS/MS (256.0 pmol/L). Accre 8 exhibited high sensitivity (96.9%) and specificity (86.7%), with Cohen's Kappa agreement (0.76). Bland-Altman analysis showed a mean bias of - 18.5%, while Passing-Bablok regression indicated proportional bias at higher concentrations (slope = 1.44). ROC analysis confirmed excellent diagnostic accuracy (AUC = 0.98). Accre 8's strong diagnostic performance, minimal calibration needs, and low sample volume requirements position it as a practical alternative to conventional CLIA systems for Vit B12 assessment, particularly in clinical and resource-limited settings. These findings support its potential integration into routine diagnostic workflows for Vit B12 deficiency screening and monitoring. |
راعي المشروع | Open Access funding provided by the Qatar National Library. |
اللغة | en |
الناشر | Nature Research |
الموضوع | Accre 8 CLIA Deficiency Immunoassay Point-of-Care Vitamin B12 |
النوع | Article |
رقم العدد | 1 |
رقم المجلد | 15 |