عرض بسيط للتسجيلة

المؤلفAlHamad, Tasneem
المؤلفYounes, Salma
المؤلفChaar, Dayana El
المؤلفNizamuddin, Parveen B.
المؤلفMohannadi, Eiman Al
المؤلفAlghanim, Asmaa
المؤلفYounes, Nadin
المؤلفAl-Dewik, Nader
المؤلفLaiwattanapaisal, Wanida
المؤلفAmmaranond, Palanee
المؤلفHawken, Phillip
المؤلفAbu-Raddad, Laith J.
المؤلفNasrallah, Gheyath K.
تاريخ الإتاحة2025-09-03T11:36:35Z
تاريخ النشر2025-08
اسم المنشورPlos One
المعرّفhttp://dx.doi.org/10.1371/journal.pone.0329796
الاقتباسAlHamad, T., Younes, S., El Chaar, D., Nizamuddin, P. B., Al Mohannadi, E., Alghanim, A., ... & Nasrallah, G. K. (2025). Comprehensive performance evaluation of four chemiluminescence immunoassays for detecting vitamin D deficiency across diverse clinical conditions. PLoS One, 20(8), e0329796.
الرقم المعياري الدولي للكتاب1932-6203
معرّف المصادر الموحدhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=105012373022&origin=inward
معرّف المصادر الموحدhttp://hdl.handle.net/10576/67012
الملخصBackground/Objectives Vitamin D deficiency is a significant global health concern, requiring accurate diagnosis. This study evaluates the performance of four chemiluminescent immunoassay (CLIA) platforms; Snibe, Roche, DiaSorin, and Architect for vitamin D measurement. Methods A total of 345 serum samples, selected to represent a broad range of vitamin D levels and diverse health conditions, including pregnancy, chronic kidney disease, and osteoporosis, were analyzed using four platforms. Diagnostic metrics, including sensitivity, specificity, and overall percent agreement (OPA), were calculated. Spearman’s rank correlation and bias assessment were performed to evaluate inter-assay agreement. Results Spearman’s rank correlations were strong to very strong across the platforms, ranging from r = 0.924 to r = 0.969, reflecting high inter-assay concordance. Pairwise comparisons indicated that Snibe demonstrated high specificity (98–99%) and strong agreement with DiaSorin (κ = 0.91), while DiaSorin maintained a favorable balance between sensitivity (86–98%) and specificity (94–99%). Roche showed consistent diagnostic characteristics, with sensitivity ranging from 93–99% and specificity from 85–96%. Architect exhibited high sensitivity (97–99%) but relatively lower specificity (81–92%). Conclusions All platforms demonstrated robust diagnostic performance. Snibe showed notably high specificity, while DiaSorin offered balanced sensitivity and specificity. These findings underscore the relative strengths of each platform and support their use in clinical evaluation of vitamin D status.
اللغةen
الناشرThe Public Library of Science (PLOS)
الموضوعchemiluminescent immunoassay
vitamin D
العنوانComprehensive performance evaluation of four chemiluminescence immunoassays for detecting vitamin D deficiency across diverse clinical conditions
النوعArticle
رقم العدد8 August
رقم المجلد20
ESSN1932-6203
dc.accessType Open Access


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة