• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Civil and Environmental Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Seismic Assessment of Existing Lowrise and Midrise Reinforced Concrete Buildings Using the 2014 Qatar Construction Specification

    Thumbnail
    Date
    2018
    Author
    AvciO.
    AlNoussM.
    Metadata
    Show full item record
    Abstract
    Qatar is considered to have predominantly low seismic activity despite being close to some of the most active seismic zones in the world, including the Zagros thrust belt. However, the strong earthquakes that have recently taken place in Iran (2013) and Afghanistan and Pakistan (2015) were felt in Qatar, highlighting the fact that the country is not immune to earthquakes. Until recently, no seismic design criteria had been established for Qatar. The only horizontal load the designers had considered was wind loading. Although national construction standards established in 2010 for Qatar did not mandate seismic requirements, a 2014 update included some seismic accelerations to be adopted for the design of new buildings, which brought up the need for examining the status of existing buildings with respect to these new requirements. This paper presents the investigation into the performances of existing RC buildings in Qatar that were not originally designed for the seismic loads associated with the 2014 criteria. The study covered low- and midrise RC buildings because they represent the majority of buildings in Qatar. For the first time in Qatar, a number of existing buildings were selected and analyzed for both wind and seismic loads in accordance with the ACI and ASCE standards with the accelerations from the 2014 Qatar construction standards update. The results showed that the 2014 seismic loads were usually more critical than the wind loads for low- and midrise RC buildings, which led to a significant increase in the demand: capacity ratios for the lateral force-resisting system members originally designed per the 2010 standards. The four buildings analyzed in this study had sufficient margins to accommodate the increase in the design forces per the 2014 update; however, other existing buildings in Qatar may not meet these standards. Also, results revealed that the lateral movements of the structures under seismic loads were significantly greater than the movements under wind loads, which may be the result of the previous building separation requirements, specified by ASCE standards, not being satisfied. If movement joints were designed for only wind or thermal loads, then adjacent buildings may collide during earthquakes.
    DOI/handle
    http://dx.doi.org/10.1061/(ASCE)AE.1943-5568.0000331
    http://hdl.handle.net/10576/12023
    Collections
    • Civil and Environmental Engineering [‎862‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video