• English
    • العربية
  • English
  • تسجيل الدخول
  • جامعة قطر
  • مكتبة جامعة قطر
  •  الصفحة الرئيسية
  • الوحدات والمجموعات
عرض التسجيلة 
  •   مركز المجموعات الرقمية لجامعة قطر
  • المستودع الرقمي لجامعة قطر
  • أكاديمية
  • إصدارات جامعة قطر
  • وقائع مؤتمرات
  • International Conference on Civil Infrastructure and Construction (CIC 2020)
  • Theme 4: Sustainability, Renovation, and Monitoring of Civil Infrastructure
  • عرض التسجيلة
  • مركز المجموعات الرقمية لجامعة قطر
  • المستودع الرقمي لجامعة قطر
  • أكاديمية
  • إصدارات جامعة قطر
  • وقائع مؤتمرات
  • International Conference on Civil Infrastructure and Construction (CIC 2020)
  • Theme 4: Sustainability, Renovation, and Monitoring of Civil Infrastructure
  • عرض التسجيلة
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Concrete Hydration Model Characterization Using Evolutionary Optimization

    Thumbnail
    عرض / فتح
    Concrete Hydration Model Characterization Using Evolutionary Optimization.pdf (2.485Mb)
    التاريخ
    2020
    المؤلف
    Sun, Qianchen
    Elshafie, Mohammed Z.E.B.
    Rui, Yi
    البيانات الوصفية
    عرض كامل للتسجيلة
    الملخص
    Pile thermal integrity assessment by means of temperature measurement has received increasing attention in recent years. The thermal integrity testing method measures temperature changes during the concrete curing process; using an appropriate concrete hydration model together with tracking temperature development during the curing process, defects within piles could be detected. However, the implementation of thermal integrity testing in practice faces, potentially, many uncertainties including undocumented concrete mixes, lack of knowledge of ground thermal properties, uncertain boundary conditions for pile, etc... These uncertainties increase the complexity of determining appropriate parameters for the hydration model, which directly affects the defect detection capacity of the method. This paper presents an inverse approach using differential evolution (DE) algorithms to determine the concrete hydration model. With this approach, the finite element (FE) analysis is integrated into the DE algorithm to generate approximate solutions that match a controlled dataset instead of approximating the concrete hydration parameters with limited prior knowledge as currently used in practice. Firstly, a field test temperature dataset with a well-defined boundary condition is selected. The temperature development corresponding to the selected dataset is then numerically simulated using an uncalibrated general hydration model. Finally, the hydration model parameters are determined using DE algorithms based on the measured and simulated temperature development as inputs. A field case study is presented in the end of this paper. The results indicate that the proposed inverse approach using DE Pile thermal integrity assessment by means of temperature measurement has received increasing attention in recent years. The thermal integrity testing method measures temperature changes during the concrete curing process; using an appropriate concrete hydration model together with tracking temperature development during the curing process, defects within piles could be detected. However, the implementation of thermal integrity testing in practice faces, potentially, many uncertainties including undocumented concrete mixes, lack of knowledge of ground thermal properties, uncertain boundary conditions for pile, etc... These uncertainties increase the complexity of determining appropriate parameters for the hydration model, which directly affects the defect detection capacity of the method. This paper presents an inverse approach using differential evolution (DE) algorithms to determine the concrete hydration model. With this approach, the finite element (FE) analysis is integrated into the DE algorithm to generate approximate solutions that match a controlled dataset instead of approximating the concrete hydration parameters with limited prior knowledge as currently used in practice. Firstly, a field test temperature dataset with a well-defined boundary condition is selected. The temperature development corresponding to the selected dataset is then numerically simulated using an uncalibrated general hydration model. Finally, the hydration model parameters are determined using DE algorithms based on the measured and simulated temperature development as inputs. A field case study is presented in the end of this paper. The results indicate that the proposed inverse approach using DE algorithms can be used effectively in thermal integrity testing.
    معرّف المصادر الموحد
    http://www.cic.qa
    DOI/handle
    http://dx.doi.org/10.29117/cic.2020.0114
    http://hdl.handle.net/10576/14700
    المجموعات
    • الهندسة المدنية [‎867‎ items ]
    • Theme 4: Sustainability, Renovation, and Monitoring of Civil Infrastructure [‎36‎ items ]

    entitlement


    مركز المجموعات الرقمية لجامعة قطر هو مكتبة رقمية تديرها مكتبة جامعة قطر بدعم من إدارة تقنية المعلومات

    اتصل بنا | ارسل ملاحظاتك
    اتصل بنا | ارسل ملاحظاتك | جامعة قطر

     

     

    الصفحة الرئيسية

    أرسل عملك التابع لجامعة قطر

    تصفح

    محتويات مركز المجموعات الرقمية
      الوحدات والمجموعات تاريخ النشر المؤلف العناوين الموضوع النوع اللغة الناشر
    هذه المجموعة
      تاريخ النشر المؤلف العناوين الموضوع النوع اللغة الناشر

    حسابي

    تسجيل الدخول

    إحصائيات

    عرض إحصائيات الاستخدام

    مركز المجموعات الرقمية لجامعة قطر هو مكتبة رقمية تديرها مكتبة جامعة قطر بدعم من إدارة تقنية المعلومات

    اتصل بنا | ارسل ملاحظاتك
    اتصل بنا | ارسل ملاحظاتك | جامعة قطر

     

     

    Video