• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • University Publications
  • QU Forum Proceedings
  • Qatar University Annual Research Forum & Exhibition
  • QUARFE 2021
  • Theme 2: Health and Biomedical Sciences
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • University Publications
  • QU Forum Proceedings
  • Qatar University Annual Research Forum & Exhibition
  • QUARFE 2021
  • Theme 2: Health and Biomedical Sciences
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Patient Specific Transcatheter Aortic Valve Replacement Therapy Pathway with Computational Fluid Structure Interaction Analysis

    Thumbnail
    View/Open
    245.pdf (794.3Kb)
    Date
    2021
    Author
    Mutlu, Onur
    Yalçın, Hüseyin Çağatay
    Metadata
    Show full item record
    Abstract
    Total cardiovascular disease (CVD) prevalence has risen dramatically from 271 million in 1990 to 523 million in 2019, and CVD fatalities rose gradually from 12.1 million in 1990 to 18.6 million in 2019. According to American Heart Association statistics, annual heart valve procedures in the United States were above 100,000 in 2013, with approximately 50,000 AV replacements. The ideal replacement valve should be durable, resistant to thrombosis, and have excellent hemodynamics features. Transcatheter aortic valve replacement (TAVR) has been introduced about two decades ago as an alternative for minimally invasive implantation of new generation bioprosthetic heart valves. Computational modeling can be used during therapy planning for the selection of appropriate replacement valves for TAVR. In this NPRP funded project, we are establishing a mechanical and FSI analysis path, for a detailed patient-specific hemodynamics analysis for TAVR, considering the most important parameters affecting TAV efficiency. This approach will enable the choice of the most suitable TAV type and deployment position for the treatment. TAV which is crimped and placed into the catheter by mechanical analysis is deployed in a patient-specific geometry in a virtual treatment then contact pressure and the stress are measured on the aortic root, stent, and aortic leaflets. TAV performance indicators are determined by FSI analysis using coupled ABAQUS and Flow-vision software. With this advanced analysis and simulation path, we expect to estimate accurately the clinical TAVR parameters such as contact pressure, contact area, principal stress, etc. before the operation during therapy planning. This approach will help clinicians in optimal valve selection for TAVR patients.
    URI
    https://doi.org/10.29117/quarfe.2021.0084
    DOI/handle
    http://hdl.handle.net/10576/24369
    Collections
    • Biomedical Research Center Research [‎787‎ items ]
    • Theme 2: Health and Biomedical Sciences [‎80‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video