A Simulink model of an active island detection technique for inverter-based distributed generation
Abstract
With the increased involvement of Distributed Power Generation Systems (DPGSs) into the conventional power system, the structure has evolved and therefore has brought in various challenges albeit improving flexibility and smartness of the system. This paper addresses modeling one of these challenges where a Simulink model for inverter-based distributed generation (IBDG) active islanding detection technique is introduced. Out of the various types of active islanding detection methods, the modeling of the general electric islanding detection method which uses the positive feedback of the voltage or frequency at the point of common coupling (PCC) for the detection of an island is presented. This methodology is modeled and applied for an IBDG connected to a low voltage distribution network. The simulation results are presented for a 20kW, three-phase IBDG showing that the system is able to detect islanding and cease the current flow from the IBDG even under critical operating condition of a close matching between the power delivered by the inverter and the load demand (zero nondetection zone operation).
Collections
- Electrical Engineering [2685 items ]
Related items
Showing items related by title, author, creator and subject.
-
Improved Discrete Definition of Quadratic Time-Frequency Distributions
O'Toole, J.M.; Mesbah, M.; Boashash, B. ( IEEE , 2010 , Article)Computation of a time-frequency distribution (TFD) requires a discrete version of the continuous distribution. This discrete TFD (DTFD) should be free from aliasing and conserve all the important mathematical properties ... -
An automatic time-frequency procedure for interference suppression by exploiting their geometrical features
Saulig, Nicoletta; Sucic, Victor; Boashash, Boualem ( IEEE , 2011 , Conference)This paper presents an adaptive method for interference suppression in the Wigner-Ville distribution. The structure of the artifacts in the Wigner-Ville distribution has been analyzed to optimally mask the signal Wigner-Ville ... -
A modified stationary reference frame-based predictive current control with zero steady-state error for LCL coupled inverter-based distributed generation systems
Ahmed, K.H.; Massoud, Ahmed; Finney, S. J.; Williams, B. W. ( IEEE , 2011 , Article)This paper proposes a modified stationary reference frame-based predictive current controller with zero steady-state error for LCL coupled inverter-based distribution generation systems. Analytical expressions for the ...