عرض بسيط للتسجيلة

المؤلفMakhlouf, Ahmed
المؤلفAlinier, Guillaume
المؤلفKerkeni, Habib
المؤلفAl Shaikh, Loua
المؤلفRachid, Ousama
تاريخ الإتاحة2022-03-24T05:34:01Z
تاريخ النشر2022
اسم المنشورJournal of Emergency Medicine, Trauma and Acute Care
المصدرqscience
الاقتباسMakhlouf A, Alinier G, Kerkeni H, Al Shaikh L, Rachid O. A protocol to investigate the stability of 0.9% sodium chloride IV fluid bags in the prehospital setting of Qatar, Journal of Emergency Medicine, Trauma & Acute Care 2022:58 http://dx.doi.org/10.5339/jemtac.2022.qhc.58
الرقم المعياري الدولي للكتاب1999-7086
الرقم المعياري الدولي للكتاب1999-7094
معرّف المصادر الموحدhttps://doi.org/10.5339/jemtac.2022.qhc.58
معرّف المصادر الموحدhttp://hdl.handle.net/10576/28980
الملخصBackground: 0.9% sodium chloride (NaCl) fluid bags are commonly stored in ambulances. Despite that the ambulances normally use air-conditioning during operational shifts, NaCl bags are exposed to deviations from the controlled environmental conditions that could affect their integrity 1,2 , as all ambulances are not constantly in use. Although stress tests performed in a laboratory Binder Convection Oven 3 showed that NaCl maintained its stability, these findings need to be validated. This study aims to develop a protocol to evaluate the thermal stability of NaCl under real-life conditions in Qatar. Methods: Key aspects were considered to subject the research samples to the routine environmental conditions under which NaCl bags are stored in ambulances. The study bags are used for research purposes only, thus should not be used on patients (to avoid hindering the work of paramedics) and need to be tested after various exposure durations. Results: The agreed-upon study protocol is to be replicated on 5 ambulances over 12 months and includes 4 collection cycles of three 500 mL NaCl study bags and three 10 ml NaCl vials following different exposure durations (Table 1). Hence, 12 NaCl bags and 12 vials marked “for research-use-only” will be stored in a locked cabinet in the ambulance patient compartment alongside a temperature and humidity data logger taking measurements every 30 minutes (Figure 1). Control samples will be stored under manufacturer's recommended conditions. Following each collection cycle from the 5 ambulances and controls, samples will be stored at 4°C and protected from light until being visually inspected (for discoloration, turbidity, bulging), diluted, and tested using ion-exchange chromatography to measure sodium and chloride levels. Conclusion: This study performed under real-life conditions will help determine the effect of exposure to actual ambulance operational conditions on NaCl bags and may have a significant impact on how they are handled in the prehospital setting in countries with a hot/arid climate.
اللغةen
الناشرHamad bin Khalifa University Press (HBKU Press)
الموضوع0.9% sodium chloride
Stability
Prehospital settings
Ambulance Service
Normal Saline
العنوانA protocol to investigate the stability of 0.9% sodium chloride IV fluid bags in the prehospital setting of Qatar
النوعArticle
رقم العدد1
رقم المجلد2022


الملفات في هذه التسجيلة

Thumbnail

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة