Analytical model of I-bar clasps for removable partial dentures
View/ Open
Publisher version (Check access options)
Check access options
Date
2021Author
Richert R.Alsheghri A.A.
Alageel O.
Caron E.
Song J.
Ducret M.
Tamimi F.
...show more authors ...show less authors
Metadata
Show full item recordAbstract
Objective: Clasps of removable partial dentures (RPDs) often suffer from fatigue stress that leads to plastic deformation, loss of retention, and RPD failure. Recently, computer-based technologies were proposed to optimize clasp geometry design. The objective of this study was to create an analytic model of I-bar clasps for computer-aided design (CAD)-RPD. Methods: The analytical model based on mechanical laws was established to simulate I-bar clasp retention, and optimize its design. The model considered the lengths of the vertical (L1) and horizontal (L2) arms of the I-bar as well as the radius (r) of its half-round cross-section. The analytical model was validated with mechanical experiments evaluating the retention of cobalt?chromium (Co?Cr) clasps in vitro and compared with finite element analysis (FEA). Results: The analytical model was in good agreement with the mechanical experiments and FEA, and showed that I-bar clasp design could provide optimal mechanical performance as long as the length of arms (L1 and L2) do not exceed 6 mm. Clasps with L1 > 8 mm and L2 > 9 mm presented stress values exceeding the fatigue limit of Co?Cr. The proposed solution was to increase the radius of I-bar to conserve the initial mechanical performance of Co?Cr. Significance: Co?Cr I-bar clasps perform best on teeth with reduced mesiodistal dimensions (canine and premolar), and their designs could be optimized to prevent stress from reaching the yield strength and the fatigue failure limit.
Collections
- Dental Medicine Research [342 items ]
Related items
Showing items related by title, author, creator and subject.
-
Evaluation of the design-driven prediction of removable partial denture retention
Alageel O.; Ashraf N.; Bessadet M.; Nicolas E.; Tamimi F. ( Mosby Inc. , 2020 , Article)Statement of problem: Removable partial dentures (RPDs) are a cost-effective treatment designed to replace missing teeth for partially edentulous patients. However, RPDs often have insufficient retention, which results in ... -
A New Scale for Rating Oral Health-Related Quality of Life in Denture Wearers
Jovanović, Milica; Janković, Slobodan; Milojević Samanović, Anđela; Gojak, Refet; Raičević, Branislava; Erić, Jelena; Milosavljević, Marko... more authors ... less authors ( Quintessence Publishing Co. Inc. , 2024 , Article)Purpose: When carrying out prosthetic rehabilitation of edentulous and partially edentulous patients, great attention is paid to the personal attitude of the patients, their satisfaction with oral health and psychosocial ... -
Patient-Reported Outcomes of Metal and Acrylic Resin Removable Partial Dentures : A Systematic Review and Meta-Analysis
Almufleh, Balqees; Emami, Elham; Alesawy, Aminah; Rodan, Rania; Morris, Martin; Umebayashi, Mayumi; Tamimi, Faleh... more authors ... less authors ( Wiley , 2020 , Article)Metal removable partial dentures (RPDs) are often considered long-term treatment options for partially edentulous patients, while acrylic resin RPDs are considered interim treatments. The aim of this review was to compare ...