• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • University Publications
  • QU Conference Proceedings
  • International Conference on Civil Infrastructure and Construction (CIC 2023)
  • Theme 2: Advances in Infrastructure Sustainability, Renovation, and Monitoring
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • University Publications
  • QU Conference Proceedings
  • International Conference on Civil Infrastructure and Construction (CIC 2023)
  • Theme 2: Advances in Infrastructure Sustainability, Renovation, and Monitoring
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Along-Wind Aerodynamic Forces on a Rectangular Plan Building in Vicinity of a Gently Sloped Two-Dimensional Hill

    Thumbnail
    View/Open
    105.pdf (602.3Kb)
    Date
    2023
    Author
    Wani, Abdul Haseeb
    Varma, Rajendra Kumar
    Ahuja, Ashok Kumar
    Metadata
    Show full item record
    Abstract
    Many engineering applications, such as wind energy distribution for optimum site selection for wind farms, pollutant dispersion, forest fire propagation and wind loads on structures in hilly terrains require a thorough understanding of the wind flow. The assessment of wind loads on buildings and structures located on exposed hill sites is a key application for understanding the effect of topography. This paper presents a wind tunnel investigation of along-wind aerodynamic forces on a rectangular plan building located near and on top of a gently sloped sinusoidal hill. The hill model has a slope equal to 15° and extends fully across the width of the wind tunnel in the direction perpendicular to the wind flow. A force measurement study is carried out on a rectangular plan rigid building model, which is placed near and on top of the hill at a total of 17 successive locations. Results measured include along-wind base shear forces and base moments. It is observed that the along-wind force gradually increases, as the building is moving closer towards the crest. The maximum along-wind base shear force for the building is reported just upstream of the crest. Increased along-wind base moment for the building up to a factor of 4.0 is observed at the crest. This paper is expected to be of great help to structural engineers for designing buildings in hilly terrains.
    URI
    https://doi.org/10.29117/cic.2023.0105
    DOI/handle
    http://hdl.handle.net/10576/46808
    Collections
    • Theme 2: Advances in Infrastructure Sustainability, Renovation, and Monitoring [‎68‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video