• English
    • العربية
  • English
  • تسجيل الدخول
  • جامعة قطر
  • مكتبة جامعة قطر
  •  الصفحة الرئيسية
  • الوحدات والمجموعات
عرض التسجيلة 
  •   مركز المجموعات الرقمية لجامعة قطر
  • المستودع الرقمي لجامعة قطر
  • أكاديمية
  • إصدارات جامعة قطر
  • وقائع مؤتمرات
  • International Conference on Civil Infrastructure and Construction (CIC 2023)
  • Theme 2: Advances in Infrastructure Sustainability, Renovation, and Monitoring
  • عرض التسجيلة
  • مركز المجموعات الرقمية لجامعة قطر
  • المستودع الرقمي لجامعة قطر
  • أكاديمية
  • إصدارات جامعة قطر
  • وقائع مؤتمرات
  • International Conference on Civil Infrastructure and Construction (CIC 2023)
  • Theme 2: Advances in Infrastructure Sustainability, Renovation, and Monitoring
  • عرض التسجيلة
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Along-Wind Aerodynamic Forces on a Rectangular Plan Building in Vicinity of a Gently Sloped Two-Dimensional Hill

    Thumbnail
    عرض / فتح
    105.pdf (602.3Kb)
    التاريخ
    2023
    المؤلف
    Wani, Abdul Haseeb
    Varma, Rajendra Kumar
    Ahuja, Ashok Kumar
    البيانات الوصفية
    عرض كامل للتسجيلة
    الملخص
    Many engineering applications, such as wind energy distribution for optimum site selection for wind farms, pollutant dispersion, forest fire propagation and wind loads on structures in hilly terrains require a thorough understanding of the wind flow. The assessment of wind loads on buildings and structures located on exposed hill sites is a key application for understanding the effect of topography. This paper presents a wind tunnel investigation of along-wind aerodynamic forces on a rectangular plan building located near and on top of a gently sloped sinusoidal hill. The hill model has a slope equal to 15° and extends fully across the width of the wind tunnel in the direction perpendicular to the wind flow. A force measurement study is carried out on a rectangular plan rigid building model, which is placed near and on top of the hill at a total of 17 successive locations. Results measured include along-wind base shear forces and base moments. It is observed that the along-wind force gradually increases, as the building is moving closer towards the crest. The maximum along-wind base shear force for the building is reported just upstream of the crest. Increased along-wind base moment for the building up to a factor of 4.0 is observed at the crest. This paper is expected to be of great help to structural engineers for designing buildings in hilly terrains.
    معرّف المصادر الموحد
    https://doi.org/10.29117/cic.2023.0105
    DOI/handle
    http://hdl.handle.net/10576/46808
    المجموعات
    • Theme 2: Advances in Infrastructure Sustainability, Renovation, and Monitoring [‎68‎ items ]

    entitlement


    مركز المجموعات الرقمية لجامعة قطر هو مكتبة رقمية تديرها مكتبة جامعة قطر بدعم من إدارة تقنية المعلومات

    اتصل بنا | ارسل ملاحظاتك
    اتصل بنا | ارسل ملاحظاتك | جامعة قطر

     

     

    الصفحة الرئيسية

    أرسل عملك التابع لجامعة قطر

    تصفح

    محتويات مركز المجموعات الرقمية
      الوحدات والمجموعات تاريخ النشر المؤلف العناوين الموضوع النوع اللغة الناشر
    هذه المجموعة
      تاريخ النشر المؤلف العناوين الموضوع النوع اللغة الناشر

    حسابي

    تسجيل الدخول

    إحصائيات

    عرض إحصائيات الاستخدام

    مركز المجموعات الرقمية لجامعة قطر هو مكتبة رقمية تديرها مكتبة جامعة قطر بدعم من إدارة تقنية المعلومات

    اتصل بنا | ارسل ملاحظاتك
    اتصل بنا | ارسل ملاحظاتك | جامعة قطر

     

     

    Video