• English
    • العربية
  • English
  • تسجيل الدخول
  • جامعة قطر
  • مكتبة جامعة قطر
  •  الصفحة الرئيسية
  • الوحدات والمجموعات
عرض التسجيلة 
  •   مركز المجموعات الرقمية لجامعة قطر
  • المستودع الرقمي لجامعة قطر
  • أكاديمية
  • مراكز البحث
  • مركز التنمية المستدامة
  • الأبحاث
  • عرض التسجيلة
  • مركز المجموعات الرقمية لجامعة قطر
  • المستودع الرقمي لجامعة قطر
  • أكاديمية
  • مراكز البحث
  • مركز التنمية المستدامة
  • الأبحاث
  • عرض التسجيلة
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Use of Electrical Resistivity Tomography to Study the Impact of Long-Term Application of Sewage Sludge: Case Study of Oued Souhil Experimental Station, Nabeul (Tunisia)

    عرض / فتح
    Use_of_Electrical_Resistivity_Tomography_2019.pdf (324.3Kb)
    التاريخ
    2022-01-01
    المؤلف
    Hechmi, Sarra
    Ghorbel, Manel
    Azaiez, Hajer
    Babbou, Chiraz
    Khelil, Mohamed Naceur
    Ghrib, Rim
    Hamdi, Helmi
    Gabtni, Hakim
    Jedidi, Naceur
    ...show more authors ...show less authors
    البيانات الوصفية
    عرض كامل للتسجيلة
    الملخص
    Soil salinization following repetitive applications of sewage sludge (S.S.) is a major environmental impediment with severe adverse impacts on agricultural productivity and sustainability, particularly in arid and semiarid regions. Electrical resistivity tomography (ERT) can be easily and rapidly assessed in the field for soil salinity investigations. Accordingly, ERT was conducted on sandy soil (soil S) in a semiarid Region in Tunisia (Oued Souhil, Nabeul) after repetitive S.S. application at the equivalent rates: 0, 40, 80, and 120 t/ha. The study aimed to monitor topsoil and subsoil salinization following the sludge trial. As such, the ERT survey was measured across each field plot of 4 m2 using the Lund System of ABEM with SAS4000 Resistivimeter. Wenner array was applied using 16 electrodes and 0.2 m electrode spacing, which corresponds to approximately 0.6 m depth of investigation. Laboratory analyses were conducted on soil samples taken in the middle of the treated plots at four depths (0–20 cm), (20–40 cm), and (40–60 cm) for a comparison with the ERT survey result. ERT panels showed a general decrease in soil resistivity below (40 cm) with extremely low resistivity in each plot’s corner, indicating a vertical leaching and a lateral migration of conductive materials in all the treatments. However, the laboratory analysis did not confirm these results, showing the decrease in soil electrical conductivity (E.C.) with soil depth in the amended soils. Soil parameters (E.C., O.M.) decreased drastically from the last amendment (in 2017), reaching lower levels than the experimental soil (before sludge trial). This fact could be attributed to the heavy rainfall recorded in Nabeul in September 2018 that caused soil leaching throughout the soil profile, as shown by the ERT panels.
    معرّف المصادر الموحد
    https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85129848133&origin=inward
    DOI/handle
    http://dx.doi.org/10.1007/978-3-030-76081-6_76
    http://hdl.handle.net/10576/48504
    المجموعات
    • الأبحاث [‎340‎ items ]

    entitlement


    مركز المجموعات الرقمية لجامعة قطر هو مكتبة رقمية تديرها مكتبة جامعة قطر بدعم من إدارة تقنية المعلومات

    اتصل بنا | ارسل ملاحظاتك
    اتصل بنا | ارسل ملاحظاتك | جامعة قطر

     

     

    الصفحة الرئيسية

    أرسل عملك التابع لجامعة قطر

    تصفح

    محتويات مركز المجموعات الرقمية
      الوحدات والمجموعات تاريخ النشر المؤلف العناوين الموضوع النوع اللغة الناشر
    هذه المجموعة
      تاريخ النشر المؤلف العناوين الموضوع النوع اللغة الناشر

    حسابي

    تسجيل الدخول

    إحصائيات

    عرض إحصائيات الاستخدام

    مركز المجموعات الرقمية لجامعة قطر هو مكتبة رقمية تديرها مكتبة جامعة قطر بدعم من إدارة تقنية المعلومات

    اتصل بنا | ارسل ملاحظاتك
    اتصل بنا | ارسل ملاحظاتك | جامعة قطر

     

     

    Video