• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Pharmacy
  • Pharmacy Research
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Pharmacy
  • Pharmacy Research
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Abbreviated Urine Collection Compared With 24-Hour Urine Collection for Measuring Creatinine Clearance in Adult Critically Ill Patients: A Systematic Review

    Thumbnail
    Date
    2024
    Author
    Saad, Mohamed Omar
    Mohamed, Adham
    Mohamed Ibrahim, Mohamed Izham
    Metadata
    Show full item record
    Abstract
    Objective: To evaluate the accuracy of abbreviated urine collection (≤12 hours) compared with 24-hour urine collection for measuring creatinine clearance (CrCl) in critically ill adult patients. Data Sources: We searched PubMed, Embase, Web of Science, Google Scholar, and ProQuest Dissertations and Thesis Global; screened reference lists of included studies; and contacted the authors when needed. English studies only were considered with no restriction on dates. Study Selection and Data Extraction: After duplicate removal, 2 reviewers screened titles/abstracts, reviewed full-text articles, and extracted data independently. Studies that compared abbreviated versus 24-hour urine collection for measuring CrCl were included. We assessed the risk of bias using the QUADAS-2 tool. We extracted correlation coefficients, mean prediction errors (ME)—as a measure of bias, and root mean squared prediction errors (RMSE)—as a measure of precision. Data Synthesis: Five studies were included, comprising 528 adult critically ill adults from surgical, medical, and trauma intensive care units (ICUs). Three studies had high risk of bias, and 2 had low risk. The studies evaluated different durations of urine collection, including 30-minute, 2-hour, 4-hour, 6-hour, and 12-hour. Mean 24-hour CrCl ranged from 57 mL/min/1.73 m2 to 103 mL/min. Abbreviated urine collection led to CrCl that correlated well with the 24-hour measured CrCl (correlation coefficient ranged from 0.8 to 0.95). Mean prediction error ranged from 5 mL/min/1.73 m2 to 16 mL/min (from 8% to 25% of the 24-hour CrCl). Root mean squared prediction error calculated from 1 study was 30.5 mL/min/1.73 m2. Relevance to Patient Care and Clinical Practice: Abbreviated urine collection is used to measure CrCl for renal drug dosing in critically ill patients, but its accuracy is not well-established. Conclusions: Abbreviated urine collection may overestimate CrCl compared with 24-hour urine collection. Larger, well-conducted studies are needed to evaluate the accuracy of CrCl measured using different durations of urine collection in critically ill patients.
    DOI/handle
    http://dx.doi.org/10.1177/10600280241241820
    http://hdl.handle.net/10576/57884
    Collections
    • Pharmacy Research [‎1426‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video