Show simple item record

AuthorAkbari, Ehsan
AuthorFakhrooeian, Mahan
AuthorJabari, Mostafa
AuthorBanazadeh, Hamidreza
AuthorAhmadi, Monireh
AuthorMuyeen, S. M.
Available date2025-01-08T09:17:24Z
Publication Date2024-01-01
Publication NameIEEE Access
Identifierhttp://dx.doi.org/10.1109/ACCESS.2024.3393832
CitationAkbari, E., Fakhrooeian, M., Jabari, M., Banazadeh, H., Ahmadi, M., & Muyeen, S. M. (2024). Improving Active Resonance Damping and Unbalanced Voltage Mitigation based on Combined DDSRF and Washout Filter in Islanded Microgrids. IEEE Access.‏
URIhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85191793037&origin=inward
URIhttp://hdl.handle.net/10576/62080
AbstractThe existence of imbalanced single- and two-phase loads, coupled with short-circuit faults, contributes to voltage imbalance. It is inevitable to use LCL filters to remove harmonics caused by converter switching. While effective in removing harmonic components, these filters may inadvertently amplify and propagate resonance. Both voltage imbalance and active resonance significantly degrade power quality. This paper proposes a multi-level hierarchical control system to mitigate both phenomena. At Level 1, the controller incorporates proportional-resonant regulators for current and voltage. Level 2 employs common droop control to establish microgrid voltage and frequency reference values. Level 3 introduces a washout filter with an adjustable Kd gain, capable of attenuating active resonance harmonics originating from the LCL filter. Finally, Level 4 integrates a controller based on extracting positive and negative sequence components using the dual decoupled synchronous reference frame (DDSRF) algorithm. This controller effectively compensates for negative sequence components of voltage in the load bus, balancing load voltage. Simulation results for a standalone microgrid demonstrate that the proposed 4-level hierarchical control algorithm can reduce the load bus voltage imbalance from 10% to 2.5% under the most challenging conditions. It diminishes harmonic distortion caused by active resonance from 11% to 2.5%. The presented control algorithm can perform optimally under dynamic changes of active and reactive power of nonlinear and imbalanced loads. The main merit of this approach is not to use physical devices and Flexible Alternative Current Transmission Systems (FACTS), such as Active Power Filters (APF), Distribution Static Synchronous Compensators (DsSTATCOM), SVC, etc.
Languageen
PublisherInstitute of Electrical and Electronics Engineers Inc.
SubjectActive resonance damping
hierarchical control
islanded microgrid
unbalanced voltage
TitleImproving Active Resonance Damping and Unbalanced Voltage Mitigation Based on Combined DDSRF and Washout Filter in Islanded Microgrids
TypeArticle
Volume Number12
dc.accessType Open Access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record