عرض بسيط للتسجيلة

المؤلفThapa, Samar
المؤلفBansal, Ajay Kumar
المؤلفPanda, Goutam Kumar
المؤلفIndraganti, Madhavi
تاريخ الإتاحة2020-03-18T08:10:07Z
تاريخ النشر2018
اسم المنشورEnergy and Buildings
المصدرScopus
الرقم المعياري الدولي للكتاب3787788
معرّف المصادر الموحدhttp://dx.doi.org/10.1016/j.enbuild.2018.05.058
معرّف المصادر الموحدhttp://hdl.handle.net/10576/13300
الملخصThermal comfort standards are required to provide comfortable indoor condition which has a positive effect on the occupant. However, the Predicted Mean Vote – Percentage People Dissatisfied (PMV-PPD) model which is used to determine the indoor comfort in most of the international standards fails often, especially in naturally ventilated buildings. Several field studies were conducted elsewhere to determine the comfort condition, but very few are reported for the cold and cloudy type of climate and in hilly region. In this paper, the results of field studies conducted in 10 buildings of different types located in varying elevation are presented. A total of 2608 responses of thermal comfort were collected from 436 subjects between January and December 2015. The mean clothing insulation of the subjects were found to increase with the increase in the elevation of the location and this difference was statistically significant, t = −94.05 (df = 2607, p < 0.001). The yearly mean clothing insulation in S0135 was 0.640 clo, K1420 was 0.722 clo, M1640 was 0.947 clo, S1950 was 1.055 clo and T2565 was 0.907 clo, respectively. Whereas, the mean comfort temperature decreased with the elevation of the location and this difference was also statistically significant, t = −92.34 (df = 2607, p < 0.001). The yearly mean comfort temperature for the location S0135 was 28.37°C, K1420 was 20.59°C, M 1640 was 20.07°C, S1950 was 19.72°C and T2565 was 17.35°C, respectively, where the digits in the locations (i.e. 0135 in S0135, 1420 in K1420, 1640 in M1640, 1950 in S1950 and 2565 in T2565) represents the elevation of the location under study in meters above mean sea level. A relation of the indoor comfort temperature with the outdoor environmental conditions and with the elevation of the location under study is obtained.
اللغةen
الناشرElsevier Ltd
الموضوعClothing insulation
Comfort temperature
Elevation
Predicted mean vote
العنوانAdaptive thermal comfort in the different buildings of Darjeeling Hills in eastern India – Effect of difference in elevation
النوعArticle
الصفحات649 - 677
رقم المجلد173


الملفات في هذه التسجيلة

الملفاتالحجمالصيغةالعرض

لا توجد ملفات لها صلة بهذه التسجيلة.

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة