    Impact of aeration rate and dielectrophoretic force on fouling suppression in submerged membrane bioreactors

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    Date
    2019
    Author
    Hawari A.H.
    Larbi B.
    Alkhatib A.
    Yasir A.T.
    Du F.
    Baune M.
    Thöming J.
    ...show more authors ...show less authors
    Metadata
    Show full item record
    Abstract
    Membrane bioreactors (MBRs) present a unique opportunity in waste water treatment by combining the activated sludge process with membrane filtration. Although MBRs require less area, produce less volume of sludge and have high purification efficiency, they suffer from high membrane fouling. Membrane fouling can be reduced by applying aeration and Dep voltage. However, application of these two anti-fouling mechanisms would make the process expensive. Thus, a new aeration and DEP scheme of 5 min on – 5 min off is being suggested in this study. With this scheme, it was found that through application of DEP at 100 V and 0.3 L/min.m2 aeration flowrate and reduced lumen size of 6 mm, the membrane permeate flux can be increased by 58% compared to MBR without DEP and aeration. However, through energy analysis the optimum operating parameters were found to be at 0.3 L/min.m2 aeration flowrate and 50 V DEP using the suggested 5 min on-5 min off scheme. At the optimum operating condition, the permeability flux is 54% higher than MBR without DEP and aeration.
    DOI/handle
    http://dx.doi.org/10.1016/j.cep.2019.107565
    http://hdl.handle.net/10576/14539
    Collections
    • Civil and Environmental Engineering [‎862‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video