    A new thermal integrity method for pile anomaly detection

    Thumbnail
    Date
    2019
    Author
    Sun, QIANCHEN
    Elshafie, MOHAMMED Z.E.B.
    Metadata
    Show full item record
    Abstract
    Anomaly detection is a hot topic in pile construction which is a complex one due to the intrinsic nature of underground structures, such as limited accessibility, large depth and complex soil profile. Several traditional pile integrity tests have been developed before, which, however, cannot give detailed information of anomaly size, nature or precise location. This paper proposes a new thermal integrity testing method that employs distributed temperature sensors and combines concrete heat hydration numerical model. The fundamental principle is that early-age concrete releases heat during curing. If defects such as voids, necking, bulging and/or soil intrusion exist inside the concrete body, they will result in local temperature variations. The developed numerical model uses Finite Element Method (FEM) to simulate concrete hydration and heat transfer. The model can be customised for different concrete mixes, pile geometries and built-in anomalies. The modelling results are then compared to field test temperature data. Any temperature disparities indicate potential anomalies of the pile structure. The proposed new test will reduce the cost and increase the accuracy compared to traditional integrity tests. It will be a promising method for the future deep foundation assessment. - 2019 by DEStech Publications, Inc. All rights reserved.
    DOI/handle
    http://dx.doi.org/10.12783/shm2019/32405
    http://hdl.handle.net/10576/15574
    Collections
    • Civil and Environmental Engineering [‎869‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video