    A non-communication based protection algorithm for multi-terminal HVDC grids

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    Date
    2017
    Author
    Abu-Elanien, Ahmed E. B.
    Abdel-Khalik, Ayman S.
    Massoud, Ahmed M.
    Ahmed, Shehab
    Metadata
    Show full item record
    Abstract
    This paper introduces a non-communication based protection algorithm for Multi-Terminal High Voltage Direct Current (MTHVDC) transmission lines. The algorithm relies on using electrical current data at one end for identification of the fault zone without communication between relays. The concept is to use the fault generated transients to differentiate between internal and external faults. Shunt capacitors with predetermined values are installed at the boundary between each two HVDC line sections to assist, together with the busbar stray capacitance, in the classification of internal faults. The high frequency transients will reach the relaying point without any attenuation if the fault is internal; nevertheless, the high frequency transients will be highly attenuated if the fault is external due to the stray capacitance and the installed shunt capacitor at the connection busbar. Discrete Wavelet Transform (DWT) is used to analyze the fault current signals. MTHVDC system modeling and relay design are carried out in the MATLAB/SIMULINK environment. The results of the proposed algorithm were highly reliable regarding different types of faults with different fault resistances and at various locations.
    DOI/handle
    http://dx.doi.org/10.1016/j.epsr.2016.11.010
    http://hdl.handle.net/10576/17194
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video