    Distance-differential protection of transmission lines connected to wind farms

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    Date
    2017
    Author
    Ghorbani, Amir
    Mehrjerdi, Hasan
    Al-Emadi, Nasser A.
    Metadata
    Show full item record
    Abstract
    Distance relays are often used in the protection of the transmission lines connected to the wind farms. The distance relay using the transmission line impedance measurement identifies the type and location of the fault. However any other factors that cause the failure of the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of these factors is the fault resistance which directly increases the measured impedance by the relay. One of the methods to eliminate relay under-reach effect is using of the trip boundaries. Trip boundaries are changing with wind variation and following with output power of the wind farms. Therefore, trip boundaries should continuously change proportional by the wind speed. In this paper, a method is provided based on the combination of distance and differential protection. In this method, using active power calculation in both ends of the transmission line, fault resistance is calculated and its effects are directly deducted from the calculated impedance by the relay. Therefore, variable trip boundaries are not needed anymore. Also in this method, unlike the technique that the trip boundaries are used, the exact location of fault and its distance from the relay also is calculated. Detailed model of a doubly-fed induction generator (DFIG) driven by a wind turbine is used in the modelling. Results of studies show that the presented method eliminates properly the mal-operation of relays under all different fault resistance conditions. Elsevier Ltd
    DOI/handle
    http://dx.doi.org/10.1016/j.ijepes.2017.01.002
    http://hdl.handle.net/10576/17505
    Collections
    • Electrical Engineering [‎2840‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video