• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Novel Approach to Non-Invasive Blood Glucose Monitoring Based on Transmittance and Refraction of Visible Laser Light

    Thumbnail
    View/Open
    Novel_Approach_to_Non-Invasive_Blood_Glucose_Monitoring_Based_on_Transmittance_and_Refraction_of_Visible_Laser_Light.pdf (7.474Mb)
    Date
    2017
    Author
    Ali, Haider
    Bensaali, Faycal
    Jaber, Fadi
    Metadata
    Show full item record
    Abstract
    Current blood glucose monitoring (BGM) techniques are invasive as they require a finger prick blood sample, a repetitively painful process that creates the risk of infection. BGM is essential to avoid complications arising due to abnormal blood glucose levels in diabetic patients. Laser light-based sensors have demonstrated a superior potential for BGM. Existing near-infrared (NIR)-based BGM techniques have shortcomings, such as the absorption of light in human tissue, higher signal-to-noise ratio, and lower accuracy, and these disadvantages have prevented NIR techniques from being employed for commercial BGM applications. A simple, compact, and cost-effective non-invasive device using visible red laser light of wavelength 650 nm for BGM (RL-BGM) is implemented in this paper. The RL-BGM monitoring device has three major technical advantages over NIR. Unlike NIR, red laser light has 30 times better transmittance through human tissue. Furthermore, when compared with NIR, the refractive index of laser light is more sensitive to the variations in glucose level concentration resulting in faster response times 7-10 s. Red laser light also demonstrates both higher linearity and accuracy for BGM. The designed RL-BGM device has been tested for both in vitro and in vivo cases and several experimental results have been generated to ensure the accuracy and precision of the proposed BGM sensor. 2013 IEEE.
    DOI/handle
    http://dx.doi.org/10.1109/ACCESS.2017.2707384
    http://hdl.handle.net/10576/37815
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video