• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Harmonic Mitigation and DC Offset Rejection for Grid-Tied DSTATCOM with CESOGI-WPF Control

    Thumbnail
    Date
    2022
    Author
    Dash, Arobinda
    Muduli, Utkal Ranjan
    Jaafari, Khaled Al
    Hosani, Khalifa Al
    Iqbal, Atif
    Behera, Ranjan Kumar
    ...show more authors ...show less authors
    Metadata
    Show full item record
    Abstract
    In the distribution network, a distribution static compensator (DSTATCOM) is used to address issues such as reactive power control, harmonic suppression, and the balancing of grid-side current. This paper presents a cascaded enhanced second-order general integrator with a prefilter (CESOGI-WPF) control technique for DSTATCOM. In addition to the prevention of non-sinusoidal load currents, the proposed control approach allows for the extraction of the positive sequence and fundamental components from distorted grid voltages. Various loading scenarios, steady-state conditions, and dynamic conditions are examined to assess the performance of the proposed controller. Based on the results of this work, the existing controllers were compared with respect to their Total Harmonic Distortion (THD), steadystate error, and computational complexity. A prototype of the proposed control scheme has been validated experimentally in a laboratory setting. It has been observed that the % THD of the grid current is maintained according to IEEE-519 harmonic standard and that the grid-Tied DSTATCOM is reliable under all load conditions. 2022 IEEE.
    DOI/handle
    http://dx.doi.org/10.1109/SGRE53517.2022.9774064
    http://hdl.handle.net/10576/43111
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video