• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effortless Totem-Pole Converter Control Using a Power Factor Correction Peak Current-Mode Controller

    Thumbnail
    View/Open
    sensors-24-04910.pdf (4.131Mb)
    Date
    2024-08-01
    Author
    Alsalemi, Abdulazeez
    Massoud, Ahmed
    Metadata
    Show full item record
    Abstract
    This paper expands a recently proposed peak current-mode (PCM) control method for a power factor correction (PFC) boost converter to include the totem-pole converter and solves the controller’s compatibility problem with the totem-pole converter by proposing three input current sensing methods. Using MATLAB/Simulink 2023b, simulation experiments on a 2 kW totem-pole converter utilizing the PFC PCM controller were carried out to assess the performance of the controller with the proposed sensing methods. The findings indicate that under steady-state conditions, all three proposed sensing methods performed input current shaping successfully and yielded nearly identical THD% of about 4.4% in the input current waveform. However, it is noteworthy that method 2, referred to as the memory method, exhibited a sluggish and less robust transient response in comparison to the swift and resilient responses observed with method 1 and method 3. Additionally, the third proposed method, which involves a single current sensor positioned across the input inductor, emerged as the optimal and cost-effective sensing solution. This method achieved the same desirable attributes of fast and robust control while utilizing only a single current sensor, a notable advantage over method 1, which employs two current sensors.
    URI
    https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85200750076&origin=inward
    DOI/handle
    http://dx.doi.org/10.3390/s24154910
    http://hdl.handle.net/10576/60176
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video