• English
    • العربية
  • العربية
  • Login
  • QU
  • QU Library
  •  Home
  • Communities & Collections
  • Help
    • Item Submission
    • Publisher policies
    • User guides
    • FAQs
  • About QSpace
    • Vision & Mission
View Item 
  •   Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  • Qatar University Digital Hub
  • Qatar University Institutional Repository
  • Academic
  • Faculty Contributions
  • College of Engineering
  • Electrical Engineering
  • View Item
  •      
  •  
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Improving participation of doubly fed induction generator in frequency regulation in an isolated power system

    Thumbnail
    View/Open
    Publisher version (You have accessOpen AccessIcon)
    Publisher version (Check access options)
    Check access options
    Date
    2018
    Author
    Amadou M.M.D.
    Mehrjerdi H.
    Saad M.
    Asber D.
    Metadata
    Show full item record
    Abstract
    An increasing penetration of renewable power resources (particularly wind farms) is observed in power systems during the last years. There is a frequency control concern with these kinds of power resources because they do not provide the so-called inertial response. Since the doubly fed induction generator (DFIG) equipped with Variable Speed Wind Turbine (VSWT) is the mostly used type of generator in wind farms, this paper proposes a new control approach allowing the DFIG to participate more efficiently in the power system frequency control. The approach consists of three steps: (1) Estimating the active power mismatch ?P0 between the active electrical power and the mechanical power which appears at the first moment after the perturbance at the DFIG, (2) based on ?P0 determine the electrical power reference Pref of the active power controller, and (3) appropriate removal of ?P0 if the power frequency deviation is above a prescribed value and the automatic generation control (AGC) is activated. The obtained simulation results on a simple 2-bus system and on IEEE 14-bus test system show that the proposed approach has several advantages over existing approaches.
    DOI/handle
    http://dx.doi.org/10.1016/j.ijepes.2018.03.011
    http://hdl.handle.net/10576/13211
    Collections
    • Electrical Engineering [‎2821‎ items ]

    entitlement


    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Home

    Submit your QU affiliated work

    Browse

    All of Digital Hub
      Communities & Collections Publication Date Author Title Subject Type Language Publisher
    This Collection
      Publication Date Author Title Subject Type Language Publisher

    My Account

    Login

    Statistics

    View Usage Statistics

    About QSpace

    Vision & Mission

    Help

    Item Submission Publisher policiesUser guides FAQs

    Qatar University Digital Hub is a digital collection operated and maintained by the Qatar University Library and supported by the ITS department

    Contact Us | Send Feedback
    Contact Us | Send Feedback | QU

     

     

    Video