عرض بسيط للتسجيلة

المؤلفLiu G.
المؤلفHou W.
المؤلفZhou C.
المؤلفYin Y.
المؤلفLu S.
المؤلفDuan C.
المؤلفLi M.
المؤلفToft E.S.
المؤلفZhang H.
تاريخ الإتاحة2020-04-05T10:53:20Z
تاريخ النشر2019
اسم المنشورJournal of Vascular Access
المصدرScopus
الرقم المعياري الدولي للكتاب11297298
معرّف المصادر الموحدhttp://dx.doi.org/10.1177/1129729819826028
معرّف المصادر الموحدhttp://hdl.handle.net/10576/13799
الملخصBackground: Recently, intracavitary electrocardiogram technology has been applied to peripherally inserted central catheter placement and demonstrates many potential advantages. However, the tip positioning accuracy of intracavitary electrocardiogram technology compared to conventional X-ray method is unknown. Objective: We did a meta-analysis to compare the tip positioning accuracy between intracavitary electrocardiogram technology and conventional X-ray method. Data sources: We searched several databases, including Cochrane Library, PubMed, Web of science, and Embase. Additional studies were identified through hand searches of bibliographies and Internet searches. All human studies published in full text, abstract, or poster form were eligible for inclusion. Search terms included peripherally inserted central catheter, PICC, intracavitary electrocardiogram, IC-ECG, EKG, ECG, and catheter tip location. Study eligibility criteria: Only randomized controlled trials of using intracavitary electrocardiogram technology versus X-ray method for peripherally inserted central catheter placement were included. All studies included adult patients aged at least 18 years. Study appraisal and synthesis methods: Independent extraction of articles by two authors using predefined data fields, including study quality indicators. Of the 178 citations identified, 5 studies that included 1672 patients met the eligibility criteria. It was found that statistical heterogeneity existed among the various studies (I2 = 16%, p < 0.00001); therefore, the fixed effect model was used in the meta-analysis (p < 0.05). The meta-analysis compared the tip positioning accuracy between intracavitary electrocardiogram technology and X-ray method and showed that intracavitary electrocardiogram technology had a better positioning accuracy (odds ratio: 2.88, 95% confidence interval: 2.15–3.87, p < 0.0001). Limitations: Only five randomized trial met inclusion criteria, and the lack of an incomplete search led to the publication bias seen in these results. Conclusion: The intracavitary electrocardiogram method had a more favorable positioning accuracy versus traditional X-ray method for peripherally inserted central catheter placement in adult patients. The intracavitary electrocardiogram can be a promising technique to guide tip positioning of peripherally inserted central catheter.
اللغةen
الناشرSAGE Publications Ltd
الموضوعcatheter tip location
Intracavitary electrocardiogram
meta-analysis
peripherally inserted central catheter
العنوانMeta-analysis of intracavitary electrocardiogram guidance for peripherally inserted central catheter placement
النوعArticle Review
الصفحات577-582
رقم العدد6
رقم المجلد20


الملفات في هذه التسجيلة

الملفاتالحجمالصيغةالعرض

لا توجد ملفات لها صلة بهذه التسجيلة.

هذه التسجيلة تظهر في المجموعات التالية

عرض بسيط للتسجيلة